EUVIMEDEUVIMED entdecken
Crossref

Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing

Christopher Reilly-Stitt iD, Ian Jennings, Steve Kitchen iD, Michael Cahillane, Christine Saunders iD, Chloe George, Tom Scorer, Isobel D Walker

International Journal of Laboratory Hematology · 2025

DOI: 10.1111/ijlh.14445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Laboratory Hematology, 2025. Verfasst von Christopher Reilly-Stitt und 7 weiteren Autor:innen. Beteiligte Einrichtung: UK NEQAS (Blood Coagulation), Sheffield, UK. Hauptthemen laut MEDLINE: Blood Platelets, Platelet Aggregation, Platelet Function Tests, Blood Preservation. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To achieve accreditation for ISO 15189, laboratories are required to either participate in EQA exercises or intra‐laboratory comparisons to meet the standard. Light transmission aggregometry performed by laboratory scientists for the clinical investigation of possible platelet function defects is time dependent. Current EQA available audits the interpretation of platelet aggregation traces.

Objectives

Could NEQAS BC provide external quality assessment (EQA) material to centres employing Light Transmission Aggregometry LTA for clinical investigation of platelet function? The use of fresh donor platelets could audit more of the analytical and post analytical aspects of light transmission aggregation than currently available.

Methods

A pool of donor platelets was split into aliquots that were distributed to testing centres across England, Scotland and Wales for testing within a 72 h window. Participating centres employed their locally validated testing methods for LTA assays, for agonists including ADP; Arachidonic acid; Collagen; Epinephrine; Ristocetin; TRAP and U46619.

Results

Five different aggregation platforms were used including: Chronolog 700; Helena Aggram; PAP‐8; Stago TA‐8V and Sysmex CN‐series. Sample packs were tested through the 72 h window with most sites performing LTA on the EQA material on day one of the three.

Conclusion

The % consensus of interpretations provided by participants for agonists including: ADP; Arachidonic acid; Collagen; Epinephrine and Ristocetin ranged from 94% to 100% indicating that the material is stable plus centres using different aggregometers returned the same clinical interpretations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood PlateletsPlatelet AggregationPlatelet Function TestsBlood PreservationCryopreservationLaboratory Proficiency TestingHumans

Stichwörter der Autor:innen

cold‐stored plateletsexternal quality assessmentlight transmission aggregation

Autor:innen und Institutionen

  • UK NEQAS (Blood Coagulation), Sheffield, UK.
  • Welsh Blood Service, Talbot Green, Llantrisant, UK.
  • University Hospital Plymouth, Plymouth, UK.
  • Centre of Defence Pathology, Royal Centre of Defence Medicine, Birmingham, UK.

ORCID-Profile: Christopher Reilly-Stitt, Steve Kitchen, Christine Saunders

Zitieren

APA

Reilly-Stitt, C., Jennings, I., Kitchen, S., Cahillane, M., Saunders, C., George, C., Scorer, T., & Walker, I. D. (2025). Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14445

Vancouver

Reilly-Stitt C, Jennings I, Kitchen S, Cahillane M, Saunders C, George C, et al. Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing. International Journal of Laboratory Hematology. 2025. doi:10.1111/ijlh.14445

BibTeX
@article{ReillyStitt2025,
  author = {Reilly-Stitt, Christopher and Jennings, Ian and Kitchen, Steve and Cahillane, Michael and Saunders, Christine and George, Chloe and Scorer, Tom and Walker, Isobel D},
  title = {Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing},
  journal = {International Journal of Laboratory Hematology},
  year = {2025},
  doi = {10.1111/ijlh.14445}
}
Kostenlos starten →