Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing
International Journal of Laboratory Hematology · 2025
DOI: 10.1111/ijlh.14445 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Laboratory Hematology, 2025. Verfasst von Christopher Reilly-Stitt und 7 weiteren Autor:innen. Beteiligte Einrichtung: UK NEQAS (Blood Coagulation), Sheffield, UK. Hauptthemen laut MEDLINE: Blood Platelets, Platelet Aggregation, Platelet Function Tests, Blood Preservation. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Background
To achieve accreditation for ISO 15189, laboratories are required to either participate in EQA exercises or intra‐laboratory comparisons to meet the standard. Light transmission aggregometry performed by laboratory scientists for the clinical investigation of possible platelet function defects is time dependent. Current EQA available audits the interpretation of platelet aggregation traces.
Objectives
Could NEQAS BC provide external quality assessment (EQA) material to centres employing Light Transmission Aggregometry LTA for clinical investigation of platelet function? The use of fresh donor platelets could audit more of the analytical and post analytical aspects of light transmission aggregation than currently available.
Methods
A pool of donor platelets was split into aliquots that were distributed to testing centres across England, Scotland and Wales for testing within a 72 h window. Participating centres employed their locally validated testing methods for LTA assays, for agonists including ADP; Arachidonic acid; Collagen; Epinephrine; Ristocetin; TRAP and U46619.
Results
Five different aggregation platforms were used including: Chronolog 700; Helena Aggram; PAP‐8; Stago TA‐8V and Sysmex CN‐series. Sample packs were tested through the 72 h window with most sites performing LTA on the EQA material on day one of the three.
Conclusion
The % consensus of interpretations provided by participants for agonists including: ADP; Arachidonic acid; Collagen; Epinephrine and Ristocetin ranged from 94% to 100% indicating that the material is stable plus centres using different aggregometers returned the same clinical interpretations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UK NEQAS (Blood Coagulation), Sheffield, UK.
- Welsh Blood Service, Talbot Green, Llantrisant, UK.
- University Hospital Plymouth, Plymouth, UK.
- Centre of Defence Pathology, Royal Centre of Defence Medicine, Birmingham, UK.
ORCID-Profile: Christopher Reilly-Stitt, Steve Kitchen, Christine Saunders
Zitieren
APA
Reilly-Stitt, C., Jennings, I., Kitchen, S., Cahillane, M., Saunders, C., George, C., Scorer, T., & Walker, I. D. (2025). Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14445
Vancouver
Reilly-Stitt C, Jennings I, Kitchen S, Cahillane M, Saunders C, George C, et al. Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing. International Journal of Laboratory Hematology. 2025. doi:10.1111/ijlh.14445
BibTeX
@article{ReillyStitt2025,
author = {Reilly-Stitt, Christopher and Jennings, Ian and Kitchen, Steve and Cahillane, Michael and Saunders, Christine and George, Chloe and Scorer, Tom and Walker, Isobel D},
title = {Cold Stored Platelets: A Solution for Platelet Aggregation External Quality Assessment/Proficiency Testing},
journal = {International Journal of Laboratory Hematology},
year = {2025},
doi = {10.1111/ijlh.14445}
}
EUVIMED