EUVIMEDEUVIMED entdecken
Übersichtsarbeit

ICSH review of internal quality control policy for blood cell counters

Richard McCafferty iD, George Cembrowski, Barbara de la Salle iD, Mingting Peng, Eloisa Urrechaga iD

International Journal of Laboratory Hematology · 2024

DOI: 10.1111/ijlh.14220 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift International Journal of Laboratory Hematology, 2024. Verfasst von Richard McCafferty und 4 weiteren Autor:innen. Beteiligte Einrichtung: St James's Hospital, Dublin, Ireland. Hauptthemen laut MEDLINE: Laboratories, Clinical Laboratory Services. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: ICSH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This paper is a report of an ICSH review of policies and practices for internal quality control (IQC) policy for haematology cell counters among regulatory bodies, cell counter manufacturers and diagnostic laboratories. It includes a discussion of the study findings and links to separate ICSH guidance for such policies and practices. The application of internal quality control (IQC) methods is an essential pre‐requisite for all clinical laboratory testing including the blood count (Full Blood Count, FBC, or Complete Blood Count, CBC).

Methods

The ICSH has gathered information regarding the current state of practice through review of published guidance from regulatory bodies, a questionnaire to six major cell counter manufacturers (Abbott Diagnostics, Beckman Coulter, Horiba Medical Diagnostic Instruments & Systems, Mindray Medical International, Siemens Healthcare Diagnostics and Sysmex Corporation) and a survey issued to 191 diagnostic laboratories in four countries (China, Republic of Ireland, Spain and the United Kingdom) on their IQC practice and approach to use of commercial IQC materials.

Results

This has revealed diversity both in guidance and in practice around the world. There is diversity in guidance from regulatory organizations in regard to IQC methods each recommends, clinical levels to use and frequency to run commercial controls, and finally recommended sources of commercial controls. The diversity in practice among clinical laboratories spans the areas of IQC methods used, derivation of target values and action limits used with control materials, and frequency of running commercial controls materials.

Conclusions

These findings and their implications for IQC Practice are discussed in this paper. They are used to inform a separate guidance document, which proposes a harmonized approach to address the issues faced by diagnostic laboratories.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaboratoriesClinical Laboratory ServicesHumansQuality ControlBlood CellsClinical Laboratory Techniques

Stichwörter der Autor:innen

ICSHcell countersgeneral haematologypolicyquality control

Autor:innen und Institutionen

  • St James's Hospital, Dublin, Ireland.
  • University of Alberta, Edmonton, Alberta, Canada.
  • UK NEQAS, Watford, UK.
  • NCCL, Beijing, China.
  • Hospital Galdakao Usansolo, Bizkaia, Spain.

ORCID-Profile: Richard McCafferty, Barbara de la Salle, Eloisa Urrechaga

Förderung

  • ICSH

Zitieren

APA

McCafferty, R., Cembrowski, G., de la Salle, B., Peng, M., & Urrechaga, E. (2024). ICSH review of internal quality control policy for blood cell counters. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14220

Vancouver

McCafferty R, Cembrowski G, de la Salle B, Peng M, Urrechaga E. ICSH review of internal quality control policy for blood cell counters. International Journal of Laboratory Hematology. 2024. doi:10.1111/ijlh.14220

BibTeX
@article{McCafferty2024,
  author = {McCafferty, Richard and Cembrowski, George and de la Salle, Barbara and Peng, Mingting and Urrechaga, Eloisa},
  title = {ICSH review of internal quality control policy for blood cell counters},
  journal = {International Journal of Laboratory Hematology},
  year = {2024},
  doi = {10.1111/ijlh.14220}
}
Kostenlos starten →