EUVIMEDEUVIMED entdecken
Crossref

Risk of Bias and Reporting Quality in BP180 / BP230 ELISA Diagnostic Studies of Bullous Pemphigoid: A Meta‐Epidemiological Study

Monika Grochowska-Rak iD, Katarzyna Kulig, Arleta Grabowska, Violetta Karlińska-Jonkisz, Paweł Racisz, Marcin Czop, Hendri H Pas, Aleksandra Lesiak, Paulina Barasińska, Marta Matych, Joanna Narbutt

International Journal of Dermatology · 09.06.2026

DOI: 10.1111/ijd.70524 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Dermatology, online erschienen am 09.06.2026. Verfasst von Monika Grochowska-Rak und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, John Paul II Provincial Hospital, Belchatow, Poland. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Uniwersytet Medyczny w Lodzi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

BP180 and BP230 enzyme‐linked immunosorbent assays (ELISA) are widely used to support the diagnosis of bullous pemphigoid (BP), yet published sensitivity and specificity vary. We assessed whether methodological limitations and incomplete reporting may contribute to optimistic “headline” accuracy estimates.

Methods

We performed a meta‐epidemiological methodological study of 18 published diagnostic accuracy studies (2004–2025) contributing 42 ELISA index tests (23 BP180, 19 BP230). Risk of bias was assessed with QUADAS‐2 and reporting quality with a 16‐item STARD‐based checklist. We summarized sensitivity and specificity and compared estimates by patient‐selection risk (low vs. high/unclear) and cut‐off type (manufacturer/prespecified vs. post hoc). No new pooled meta‐analysis of diagnostic accuracy was performed.

Results

Patient selection was at high risk of bias in 15/18 studies (83%), and no study was judged low risk in the QUADAS‐2 index test domain. Key safeguards were rarely reported: blinding 6/42 tests (14%), participant flow diagram 0/42 (0%), and indeterminate/missing results 14/42 (33%). Median sensitivity/specificity were 0.82/0.94 (BP180) and 0.58/0.98 (BP230). BP180 sensitivity tended to be lower in low‐risk versus high/unclear‐risk patient‐selection studies (0.69 vs. 0.84; p = 0.09; n = 3 low‐risk studies).

Conclusions

Published ELISA accuracy—especially sensitivity—may be overestimated; in practice, a negative ELISA should not be used to rule out BP when clinical suspicion is high. image

Schlagwörter

Stichwörter der Autor:innen

BP180BP230ELISAQUADAS‐2STARDbullous pemphigoiddiagnostic accuracymeta‐epidemiology

Autor:innen und Institutionen

  • Department of Dermatology, John Paul II Provincial Hospital, Belchatow, Poland.
  • Department of Clinical Genetics, Medical University of Lublin, Lublin, Poland.
  • Center for Blistering Diseases, Department of Dermatology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
  • Laboratory of Autoinflammatory, Genetic and Rare Skin Disorders, Department of Dermatology, Pediatric Dermatology and Dermatological Oncology, Medical University of Lodz, Lodz, Poland.
  • Department of Dermatology, Pediatric Dermatology and Oncology, Medical University of Lodz, Lodz, Poland.

ORCID-Profile: Monika Grochowska-Rak

Förderung

  • Uniwersytet Medyczny w Lodzi

Zitieren

APA

Grochowska-Rak, M., Kulig, K., Grabowska, A., Karlińska-Jonkisz, V., Racisz, P., Czop, M., Pas, H. H., Lesiak, A., Barasińska, P., Matych, M., & Narbutt, J. (2026). Risk of Bias and Reporting Quality in BP180 / BP230 ELISA Diagnostic Studies of Bullous Pemphigoid: A Meta‐Epidemiological Study. International Journal of Dermatology. https://doi.org/10.1111/ijd.70524

Vancouver

Grochowska-Rak M, Kulig K, Grabowska A, Karlińska-Jonkisz V, Racisz P, Czop M, et al. Risk of Bias and Reporting Quality in BP180 / BP230 ELISA Diagnostic Studies of Bullous Pemphigoid: A Meta‐Epidemiological Study. International Journal of Dermatology. 2026. doi:10.1111/ijd.70524

BibTeX
@article{GrochowskaRak2026,
  author = {Grochowska-Rak, Monika and Kulig, Katarzyna and Grabowska, Arleta and Karlińska-Jonkisz, Violetta and Racisz, Paweł and Czop, Marcin and Pas, Hendri H and Lesiak, Aleksandra and Barasińska, Paulina and Matych, Marta and Narbutt, Joanna},
  title = {Risk of Bias and Reporting Quality in BP180 / BP230 ELISA Diagnostic Studies of Bullous Pemphigoid: A Meta‐Epidemiological Study},
  journal = {International Journal of Dermatology},
  year = {2026},
  doi = {10.1111/ijd.70524}
}
Kostenlos starten →