Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis

Monika Grochowska-Rak iD, Katarzyna Kulig, Arleta Grabowska, Violetta Karlińska-Jonkisz, Paweł Racisz iD, Marcin Czop iD, Hendri H Pas iD, Aleksandra Lesiak iD, Paulina Barasińska iD, Marta Matych, Joanna Narbutt iD

International Journal of Dermatology · 2025

DOI: 10.1111/ijd.70136 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift International Journal of Dermatology, 2025. Verfasst von Monika Grochowska-Rak und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, John Paul II Provincial Hospital, Belchatow, Poland. Hauptthemen laut MEDLINE: Autoantibodies, Collagen Type XVII, Dystonin, Pemphigoid, Bullous. Die Arbeit nennt 44 Literaturangaben. Gefördert von: statutory funds of the Medical University of Lodz.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bullous pemphigoid (BP) is the most common autoimmune blistering disorder, mainly affecting elderly patients. Enzyme‐linked immunosorbent assays (ELISA) targeting BP180 and BP230 autoantibodies are widely used in clinical practice, but their diagnostic accuracy has varied across studies. We conducted a systematic review and meta‐analysis to evaluate the pooled diagnostic performance of these assays. Following PRISMA 2020 guidelines, we searched PubMed, Embase, and CENTRAL up to January 12, 2025, for studies assessing BP180 and/or BP230 ELISA in patients with clinically and/or immunopathologically confirmed BP. Seventeen studies including 1768 BP patients and 1382 controls met the inclusion criteria. Data extraction and risk of bias assessment were performed independently by two reviewers, and pooled estimates were calculated using a bivariate random‐effects model. For BP180 ELISA, pooled sensitivity was 82.0% (95% confidence interval [CI]: 75.9%–86.8%) and specificity 94.1%. In contrast, BP230 ELISA demonstrated lower sensitivity at 58.6% (95% CI: 51.2%–65.7%) but maintained high specificity of 94.8% (95% CI 89.0–97.7). Risk of bias was generally low. Certainty of evidence, assessed with GRADE, was rated high for BP180 and low for BP230 due to imprecision and publication bias. Overall, BP180 ELISA shows high diagnostic accuracy and supports its use as a reliable, non‐invasive diagnostic tool in routine practice. BP230 ELISA, although less sensitive, is best used as an adjunctive/confirmatory assay. These findings highlight the clinical value of serological assays in the diagnostic workup of bullous pemphigoid.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AutoantibodiesCollagen Type XVIIDystoninPemphigoid, BullousHumansEnzyme-Linked Immunosorbent AssaySensitivity and Specificity

Stichwörter der Autor:innen

BP180BP230ELISAblistering diseasesbullous pemphigoiddiagnostic accuracy

Substanzen

AutoantibodiesCollagen Type XVIIDST protein, humanDystonin

Autor:innen und Institutionen

  • Department of Dermatology, John Paul II Provincial Hospital, Belchatow, Poland.
  • Department of Clinical Genetics, Medical University of Lublin, Lublin, Poland.
  • Center for Blistering Diseases, Department of Dermatology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
  • Laboratory of Autoinflammatory, Genetic and Rare Skin Disorders, Department of Dermatology, Pediatric Dermatology and Dermatological Oncology, Medical University of Lodz, Lodz, Poland.
  • Department of Dermatology, Pediatric Dermatology and Oncology, Medical University of Lodz, Lodz, Poland.

ORCID-Profile: Monika Grochowska-Rak, Paweł Racisz, Marcin Czop, Hendri H Pas, Aleksandra Lesiak, Paulina Barasińska, Joanna Narbutt

Förderung

  • statutory funds of the Medical University of Lodz

Zitieren

APA

Grochowska-Rak, M., Kulig, K., Grabowska, A., Karlińska-Jonkisz, V., Racisz, P., Czop, M., Pas, H. H., Lesiak, A., Barasińska, P., Matych, M., & Narbutt, J. (2025). Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis. International Journal of Dermatology. https://doi.org/10.1111/ijd.70136

Vancouver

Grochowska-Rak M, Kulig K, Grabowska A, Karlińska-Jonkisz V, Racisz P, Czop M, et al. Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis. International Journal of Dermatology. 2025. doi:10.1111/ijd.70136

BibTeX
@article{GrochowskaRak2025,
  author = {Grochowska-Rak, Monika and Kulig, Katarzyna and Grabowska, Arleta and Karlińska-Jonkisz, Violetta and Racisz, Paweł and Czop, Marcin and Pas, Hendri H and Lesiak, Aleksandra and Barasińska, Paulina and Matych, Marta and Narbutt, Joanna},
  title = {Sensitivity and Specificity of ELISA Tests Detecting BP180 and BP230 Antibodies in the Diagnosis of Bullous Pemphigoid: A Systematic Review and Meta‐Analysis},
  journal = {International Journal of Dermatology},
  year = {2025},
  doi = {10.1111/ijd.70136}
}
Kostenlos starten →