EUVIMEDEUVIMED entdecken
Vergleichsstudie

Full Working Length Negotiation in Challenging Narrow Canals Using a Single Conservative Asymmetric Reciprocating Instrument

Felipe Gonçalves Belladonna iD, Marco Simões-Carvalho iD, Mário Luis Zuolo, Maria Cristina Carvalho, Iracema Cabral Ehrhardt iD, Cristiane Prado Galdeano, Tiago de Mello Guimarães iD, Emmanuel João Nogueira Leal Silva iD, Erick Miranda Souza iD, Marco Aurélio Versiani iD

International Endodontic Journal · 2026

DOI: 10.1111/iej.70228 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Endodontic Journal, 2026. Verfasst von Felipe Gonçalves Belladonna und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Fluminense Federal University, Rio de Janeiro, Brazil. Hauptthemen laut MEDLINE: Root Canal Preparation, Molar, Dental Instruments, Dental Pulp Cavity. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To compare the ability of Reciproc Minima instruments (sizes 20 and 25) and Reciproc Blue R25 to reach the full working length (FWL) in the mesial canals of mandibular molars without prior scouting or glide path preparation. Methodology A total of 330 mesial canals from 165 extracted mandibular molars were included. Teeth with curvature of 0°–20° were randomly allocated to three groups ( n = 110 canals): Reciproc Blue R25, Reciproc Minima 25, or Reciproc Minima 20. No scouting or glide path preparation was performed. Canal preparation was carried out in reciprocating motion according to the manufacturers' instructions. In canals where Reciproc Blue R25 failed to reach the FWL, Reciproc Minima 25 and, if necessary, Reciproc Minima 20 were used. The primary outcome was the frequency of reaching the FWL. Secondary outcomes included instrument fracture, deformation, and preparation time. Canals in which the FWL was not reached were analysed by micro‐CT to investigate anatomical factors. Data were analysed using chi‐squared, Kruskal–Wallis, Bonferroni post hoc, and McNemar tests ( α = 0.05).

Results

The frequency of reaching the FWL differed significantly among the instruments ( p < 0.001). Reciproc Blue R25 reached the FWL in 70.91% of canals, Reciproc Minima 25 in 83.64%, and Reciproc Minima 20 in 96.36%. No instrument fractures occurred, and deformation rates were low and comparable among groups ( p = 0.552). Among canals in which Reciproc Blue R25 failed to reach the FWL, Reciproc Minima 25 failed to reach the FWL in all cases. However, Reciproc Minima 20 subsequently achieved the FWL in 78.13% and 83.33% of Reciproc Blue R25 and Reciproc Minima 25 cases, respectively ( p < 0.001). Preparation time also differed significantly among groups ( p < 0.001), with Reciproc Minima 20 reaching the FWL faster than both Reciproc Blue R25 and Reciproc Minima 25.

Conclusions

Reciproc Minima instruments showed greater ability than Reciproc Blue R25 to mechanically scout mesial canals of mandibular molars. Reciproc Minima 20 showed the highest frequency of reaching the FWL, including in canals where larger instruments failed, without increasing deformation or fracture and with shorter preparation times.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal PreparationMolarDental InstrumentsDental Pulp CavityHumansX-Ray MicrotomographyEquipment Design

Stichwörter der Autor:innen

Reciprocasymmetric reciprocationcanal scoutingmandibular molarsnickel‐titanium instruments

Autor:innen und Institutionen

  • Department of Endodontics, Fluminense Federal University, Rio de Janeiro, Brazil.
  • Private Practice, São Paulo, Brazil.
  • Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil.
  • Department of Dentistry II, Federal University of Maranhão, São Luís, Brazil.
  • Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil.

ORCID-Profile: Felipe Gonçalves Belladonna, Marco Simões-Carvalho, Iracema Cabral Ehrhardt, Tiago de Mello Guimarães, Emmanuel João Nogueira Leal Silva, Erick Miranda Souza, Marco Aurélio Versiani

Zitieren

APA

Belladonna, F. G., Simões-Carvalho, M., Zuolo, M. L., Carvalho, M. C., Ehrhardt, I. C., Galdeano, C. P., de Mello Guimarães, T., Silva, E. J. N. L., Souza, E. M., & Versiani, M. A. (2026). Full Working Length Negotiation in Challenging Narrow Canals Using a Single Conservative Asymmetric Reciprocating Instrument. International Endodontic Journal. https://doi.org/10.1111/iej.70228

Vancouver

Belladonna FG, Simões-Carvalho M, Zuolo ML, Carvalho MC, Ehrhardt IC, Galdeano CP, et al. Full Working Length Negotiation in Challenging Narrow Canals Using a Single Conservative Asymmetric Reciprocating Instrument. International Endodontic Journal. 2026. doi:10.1111/iej.70228

BibTeX
@article{Belladonna2026,
  author = {Belladonna, Felipe Gonçalves and Simões-Carvalho, Marco and Zuolo, Mário Luis and Carvalho, Maria Cristina and Ehrhardt, Iracema Cabral and Galdeano, Cristiane Prado and de Mello Guimarães, Tiago and Silva, Emmanuel João Nogueira Leal and Souza, Erick Miranda and Versiani, Marco Aurélio},
  title = {Full Working Length Negotiation in Challenging Narrow Canals Using a Single Conservative Asymmetric Reciprocating Instrument},
  journal = {International Endodontic Journal},
  year = {2026},
  doi = {10.1111/iej.70228}
}
Kostenlos starten →