Vergleichsstudie in der Zeitschrift International Endodontic Journal, 2026. Verfasst von Filipa Neto und 9 weiteren Autor:innen. Beteiligte Einrichtung: Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal. Hauptthemen laut MEDLINE: Root Canal Preparation, Dental Instruments. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Aim
To evaluate and compare the geometric characteristics, metallurgical properties, mechanical performance, and biomechanical behaviour of a reduced‐taper reciprocating instrument with six commercially available systems. Methodology A total of 441 new nickel‐titanium (NiTi) instruments from seven reciprocating systems (Excalibur 25/.05, Flash 25/.06vt, One RECI N25, Reciproc R25, Reciproc Blue R25, Reciproc Minima M25, and WaveOne Gold Primary) were analysed. Geometric design was assessed through photographic analysis, scanning electron microscopy, and high‐resolution three‐dimensional optical scanning to obtain dimensional measurements along the active blade. Metallurgical characteristics were investigated using energy‐dispersive X‐ray spectroscopy and differential scanning calorimetry. Mechanical performance was evaluated through cyclic fatigue, torsional resistance, bending resistance, buckling resistance, cutting efficiency, and microhardness tests ( n = 10 per parameter). In addition, finite element analysis was conducted using a micro‐CT‐derived mandibular premolar model to assess maximum principal stress distribution and deformation following simulated canal preparations produced by each instrument. Data distribution was analysed using the Shapiro–Wilk test, and intergroup comparisons were performed with the Kruskal‐Wallis test (α = 0.05).
Results
All instruments presented nearly equiatomic NiTi composition and distinct phase transformation temperatures. Reciproc Minima M25 showed smaller blade volume and surface area compared with the other systems. Significant differences were detected among instruments for all mechanical parameters ( p < 0.05). Reciproc Minima M25 demonstrated the longest time to fracture during cyclic fatigue testing and the highest angular rotation before fracture, as well as the lowest bending load, indicating greater flexibility. Reciproc R25 exhibited the highest torsional and buckling resistance. Flash 25/.06vt showed the lowest cyclic fatigue resistance, whereas One RECI N25 presented the highest cutting efficiency. Finite element analysis revealed similar stress patterns across models; however, larger preparation volumes tended to generate higher dentinal stresses, whereas conservative preparations were associated with lower stress concentrations.
Conclusion
The reduced‐taper Reciproc Minima M25 exhibited high cyclic fatigue resistance and flexibility while maintaining a high torsional performance comparable to other instruments. Its reduced taper and smaller blade volume were associated with slightly lower stress values in the surrounding dentine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
- Grupo de Investigação em Bioquimica e Biologia Oral, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Universidade de Lisboa, Lisboa, Portugal.
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE)-Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
- LIBPhys-FCT UID/FIS/04559/2013 (https://doi.org/10.54499/UIDB/04559/2020), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal.
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal.
- Laboratório Associado de Sistemas Inteligentes, LASI, Guimarães, Portugal.
ORCID-Profile: Filipa Neto, Jorge N R Martins, Ricardo Pinto, Emmanuel João Nogueira Leal Silva
Zitieren
APA
Neto, F., Martins, J. N. R., Martins, R. F., Rito Pereira, M., Pinto, R., Marques, D., Braz Fernandes, F. M., Silva, E. J. N. L., Versiani, M. A., & Ginjeira, A. (2026). Mechanical Performance and Biomechanical Implications of a Reduced‐Taper Reciprocating Instrument Compared With 6 Reciprocating Systems. International Endodontic Journal. https://doi.org/10.1111/iej.70184
Vancouver
Neto F, Martins JNR, Martins RF, Rito Pereira M, Pinto R, Marques D, et al. Mechanical Performance and Biomechanical Implications of a Reduced‐Taper Reciprocating Instrument Compared With 6 Reciprocating Systems. International Endodontic Journal. 2026. doi:10.1111/iej.70184
BibTeX
@article{Neto2026,
author = {Neto, Filipa and Martins, Jorge N R and Martins, Rui F and Rito Pereira, Mário and Pinto, Ricardo and Marques, Duarte and Braz Fernandes, Francisco Manuel and Silva, Emmanuel João Nogueira Leal and Versiani, Marco Aurélio and Ginjeira, António},
title = {Mechanical Performance and Biomechanical Implications of a Reduced‐Taper Reciprocating Instrument Compared With 6 Reciprocating Systems},
journal = {International Endodontic Journal},
year = {2026},
doi = {10.1111/iej.70184}
}
EUVIMED