Effect of Voxel Size on Cone‐Beam Computed Tomography‐Based Assessment of Root Canal Anatomy: A Systematic Review and Meta‐Analysis
International Endodontic Journal · 2026-04 · 59 (4) · 574-589
DOI: 10.1111/iej.70092 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift International Endodontic Journal, online erschienen am 09.01.2026. Verfasst von Hossein Mohammad-Rahimi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Dental Pulp Cavity. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Aarhus Universitet.
Abstract (Originalsprache)
Introduction
Cone‐beam computed tomography (CBCT) has become an integral part of endodontic diagnosis and treatment, with voxel size being a critical parameter affecting spatial resolution and diagnostic outcomes. This systematic review and meta‐analysis examined the effect of voxel size on the diagnostic outcome of CBCT images for root canal anatomy assessment.
Methods
A search was conducted in PubMed, Web of Science, Embase, and Scopus databases without date restrictions. Studies comparing different CBCT voxel sizes for root canal anatomy evaluation using quantitative diagnostic outcomes were included. Two reviewers independently performed study selection, data extraction, and quality assessment using QUADAS‐2. Meta‐analysis was conducted using random‐effects models with subgroup analysis by voxel size categories (≤ 125 μm and > 125 μm).
Results
Fifteen studies met the inclusion criteria, evaluating voxel sizes from 75 to 400 μm across various anatomical structures. Seven studies were included in the meta‐analysis. Individual studies consistently demonstrated improved visualisation with smaller voxel sizes, particularly for larger structures such as second mesiobuccal canals in maxillary molars. Overall pooled diagnostic accuracy was 80% (95% CI: 75%–84%) with substantial heterogeneity ( I 2 = 86.74%). Subgroup analysis showed diagnostic accuracy of 75% (95% CI: 68%–82%) for voxel sizes > 125 μm and 85% (95% CI: 80%–90%) for voxel sizes ≤ 125 μm. The difference between the two groups was statistically significant ( p = 0.002). Moreover, meta‐regression showed a statistically significant association between voxel size and diagnostic accuracy ( p = 0.0086).
Conclusions
The current study's findings suggest that there is an association between reducing the voxel size and enhancing the diagnostic outcome of CBCT images in assessing root canal anatomy. Although the meta‐regression showed a statistically significant correlation, the results should be interpreted cautiously because of methodological heterogeneity, the complex interplay of imaging parameters beyond voxel size alone, and the lack of clinical studies. Future research should focus on standardised clinical studies to examine the impact of voxel size on the diagnostic outcome of CBCT images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark.
- Department of Conservative Dentistry, Periodontology and Digital Dentistry, LMU Munich, LMU University Hospital, Munich, Germany.
- Center for Craniofacial Molecular Biology, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California, USA.
- Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, Maryland, USA.
- Private Practice in Endodontics, Centreville Endodontics, Centreville, Virginia, USA.
ORCID-Profile: Hossein Mohammad-Rahimi, Rubens Spin-Neto, Ruben Pauwels
Förderung
- Aarhus Universitet
Zitieren
APA
Mohammad-Rahimi, H., Ourang, S. A., Nosrat, A., Spin-Neto, R., & Pauwels, R. (2026). Effect of Voxel Size on Cone‐Beam Computed Tomography‐Based Assessment of Root Canal Anatomy: A Systematic Review and Meta‐Analysis. International Endodontic Journal, 59(4), 574-589. https://doi.org/10.1111/iej.70092
Vancouver
Mohammad-Rahimi H, Ourang SA, Nosrat A, Spin-Neto R, Pauwels R. Effect of Voxel Size on Cone‐Beam Computed Tomography‐Based Assessment of Root Canal Anatomy: A Systematic Review and Meta‐Analysis. International Endodontic Journal. 2026;59(4):574-589. doi:10.1111/iej.70092
BibTeX
@article{MohammadRahimi2026,
author = {Mohammad-Rahimi, Hossein and Ourang, Seyed AmirHossein and Nosrat, Ali and Spin-Neto, Rubens and Pauwels, Ruben},
title = {Effect of Voxel Size on Cone‐Beam Computed Tomography‐Based Assessment of Root Canal Anatomy: A Systematic Review and Meta‐Analysis},
journal = {International Endodontic Journal},
year = {2026},
volume = {59},
number = {4},
pages = {574--589},
doi = {10.1111/iej.70092}
}
EUVIMED