EUVIMEDEUVIMED entdecken
Vergleichsstudie

Micro‐CT evaluation of the effect of various ScRp instrumentation methods on cement loss, porosity and micro‐crack formation

Hasan Yıldız, Nilsun Bagis, Melike Camgoz, Fatma Karacaoglu iD, Mert Ocak, Kaan Orhan

International Journal of Dental Hygiene · 2024

DOI: 10.1111/idh.12712 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Journal of Dental Hygiene, 2024. Verfasst von Hasan Yıldız und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology, Faculty of Dentistry, Ankara University, Ankara, Turkey. Hauptthemen laut MEDLINE: X-Ray Microtomography, Dental Scaling. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The purpose of this study was to compare the effectiveness of three different instruments on cement loss, porosity and micro‐crack formation, which was not evaluated before, following scaling and root planning (SRP) using micro‐computed tomography (micro‐CT).

Methods

In this experimental study, 30 single‐rooted extracted human teeth were used and divided into three groups. All the teeth were scanned with micro‐CT before and after SRP. Group 1: SRP was performed with Gracey curettes, Group 2: SRP was performed by using an ultrasonic device, and Group 3: SRP was performed by using diamond burs. Cement loss from the root surface, porosity, and micro‐crack formation in the root dentine were analysed. Micro‐CT is used for qualitative and quantitative analysis of samples. The obtained data were analysed statistically ( p < 0.05).

Results

Minimum cement loss following SRP was detected with ultrasonic scaler (26.98 mm 3 ), whereas the highest was created by diamond burs (96.20 mm 3 ) ( p < 0.05). The total porosity values after SRP were 0.278%, 0.334% and 0.252% for Groups 1, 2 and 3, respectively. Although Group 3 had the least porosity values, there was no statistically significant difference between the groups. The highest micro‐crack formation was seen in Group 2 and the lowest was in Group 1 with a significant difference ( p < 0.05).

Conclusions

More cement loss was observed with diamond burs. Ultrasonic devices appear to be a viable alternative to instrumentation with curettes. However, ultrasonic devices should be used carefully because of micro‐crack formation since the micro‐crack resulting from instrumentation with hand instruments is the least of all.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyDental ScalingPorosityHumansRoot PlaningDental CementsIn Vitro TechniquesTooth RootDentin

Stichwörter der Autor:innen

microCTmicrocrackscaling and root planning, porosity, surface roughness, Gracey curetteultrasonic scaler

Substanzen

Dental Cements

Autor:innen und Institutionen

  • Department of Periodontology, Faculty of Dentistry, Ankara University, Ankara, Turkey.
  • Faculty of Dentistry, Gazi University, Ankara, Turkey.
  • Department of Anatomy, Faculty of Dentistry, Ankara University, Ankara, Turkey.
  • Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.
  • Ankara University Medical Design Application and Research Center (MEDITAM), Ankara, Turkey.

ORCID-Profile: Fatma Karacaoglu

Zitieren

APA

Yıldız, H., Bagis, N., Camgoz, M., Karacaoglu, F., Ocak, M., & Orhan, K. (2024). Micro‐CT evaluation of the effect of various ScRp instrumentation methods on cement loss, porosity and micro‐crack formation. International Journal of Dental Hygiene. https://doi.org/10.1111/idh.12712

Vancouver

Yıldız H, Bagis N, Camgoz M, Karacaoglu F, Ocak M, Orhan K. Micro‐CT evaluation of the effect of various ScRp instrumentation methods on cement loss, porosity and micro‐crack formation. International Journal of Dental Hygiene. 2024. doi:10.1111/idh.12712

BibTeX
@article{Yldz2024,
  author = {Yıldız, Hasan and Bagis, Nilsun and Camgoz, Melike and Karacaoglu, Fatma and Ocak, Mert and Orhan, Kaan},
  title = {Micro‐CT evaluation of the effect of various ScRp instrumentation methods on cement loss, porosity and micro‐crack formation},
  journal = {International Journal of Dental Hygiene},
  year = {2024},
  doi = {10.1111/idh.12712}
}
Kostenlos starten →