The Accuracy of Melting Curve–Based Multiplex Real‐Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens
Helicobacter · 2025
DOI: 10.1111/hel.70012 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Helicobacter, 2025. Verfasst von Youhua Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Jiangxi Provincial Key Laboratory of Digestive Diseases, Jiangxi Clinical Research Center for Gastroenterology, Diges…. Hauptthemen laut MEDLINE: Levofloxacin, Clarithromycin, Helicobacter pylori, Anti-Bacterial Agents. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Research Project of Jiangxi Provincial Department of Education.
Abstract (Originalsprache)
Aims
This study evaluates the accuracy of melting curve–based multiplex real‐time PCR (multiplex rt‐PCR) on stool samples for diagnosing antibiotic resistance in Helicobacter pylori ( H. pylori ) compared to E‐test and sequencing.
Methods
Gastric biopsies and stool samples were collected from 385 H. pylori ‐infected patients. A total of 325 strains were isolated, and genomic DNA was extracted from all 385 stool samples. E‐tests were conducted to detect phenotypic resistance for clarithromycin and levofloxacin. Sanger sequencing and multiplex rt‐PCR were employed to identify H. pylori 23S rRNA and GyrA mutations.
Results
E‐test results indicated that 203 (62.5%) were susceptible to both clarithromycin and levofloxacin, 33 (10.2%) exhibited mono‐resistance to clarithromycin, 48 (14.8%) showed mono‐resistance to levofloxacin, and 41 (12.6%) had dual resistance to both antibiotics. Compared to E‐test results, the sensitivity and specificity of the multiplex rt‐PCR method for detecting clarithromycin resistance mutation were 93.2 (95% CI 84.3–97.5) and 87.1% (95% CI 82.2–90.9), respectively. For levofloxacin resistance mutation, the multiplex rt‐PCR method showed a sensitivity of 80.7 (95% CI 70.3–88.3) and a specificity of 93.0% (95% CI 88.7–95.8). Compared to Sanger sequencing, the sensitivity and specificity of the multiplex rt‐PCR method for detecting clarithromycin resistance mutation were 95.8 (95% CI 90.0–98.4) and 96.0% (95% CI 92.6–98.0), respectively. For levofloxacin resistance mutation, the multiplex rt‐PCR method showed a sensitivity of 91.3% (95% CI, 83.1–95.9) and a specificity of 96.1% (95% CI, 92.7–98.0).
Conclusion
Genotypic methods, including Sanger sequencing and multiplex rt‐PCR, were rapid and reliable for diagnosing clarithromycin and levofloxacin resistance in the stool samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Gastroenterology, Jiangxi Provincial Key Laboratory of Digestive Diseases, Jiangxi Clinical Research Center for Gastroenterology, Digestive Disease Hospital, the First Affiliated Hospital, Jiangxi Medical…
- Huan Kui College of Nanchang University, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi Province, China.
- Jiangsu GeneWill Diagnostics Company Limited, Jiangsu Province, China.
ORCID-Profile: Yong Xie
Förderung
- National Natural Science Foundation of China
- Science and Technology Research Project of Jiangxi Provincial Department of Education
Zitieren
APA
Wang, Y., Gong, X., Lai, Q., Fang, H., Yang, X., Li, X., Liu, D. S., & Xie, Y. (2025). The Accuracy of Melting Curve–Based Multiplex Real‐Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens. Helicobacter. https://doi.org/10.1111/hel.70012
Vancouver
Wang Y, Gong X, Lai Q, Fang H, Yang X, Li X, et al. The Accuracy of Melting Curve–Based Multiplex Real‐Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens. Helicobacter. 2025. doi:10.1111/hel.70012
BibTeX
@article{Wang2025,
author = {Wang, Youhua and Gong, Xiaoling and Lai, Qirui and Fang, Hui and Yang, Xiyin and Li, Xuan and Liu, Dong Sheng and Xie, Yong},
title = {The Accuracy of Melting Curve–Based Multiplex Real‐Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens},
journal = {Helicobacter},
year = {2025},
doi = {10.1111/hel.70012}
}
EUVIMED