EUVIMEDEUVIMED entdecken
Crossref

Mesoscale CISS imaging for the detection of dural defects in spinal CSF leaks: A retrospective case series

Michelle L Wegscheid, Zack Nigogosyan, Arindam R Chatterjee, Cyrus A Raji, Martin N Reis, Nicholas P Fleege, Sherwin N Azad, Benjamin A Plog, John Ogunlade, Ananth K Vellimana, Manu S Goyal, Arash Nazeri iD

Headache: The Journal of Head and Face Pain · 2026-07 · 66 (7) · 1563-1574

DOI: 10.1111/head.70123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Headache: The Journal of Head and Face Pain, online erschienen am 06.05.2026. Verfasst von Michelle L Wegscheid und 11 weiteren Autor:innen. Beteiligte Einrichtung: Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA. Hauptthemen laut MEDLINE: Cerebrospinal Fluid Leak, Dura Mater, Magnetic Resonance Imaging, Magnetic Resonance Myelography. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This retrospective, single‐center, descriptive case series evaluates early adoption of a two‐stage spine MRI protocol incorporating high‐resolution, three‐dimensional mesoscale constructive interference in steady state (meso‐CISS) for targeted cerebrospinal fluid (CSF) leak localization.

Background

Spontaneous intracranial hypotension (SIH) results from CSF leaks at the spinal canal, yet precise localization of dural defects remains challenging. Although fat‐saturated heavily T2‐weighted magnetic resonance (MR) myelography (HT2‐MRM) is sensitive to spinal longitudinal extradural CSF collections (SLECs), it does not reliably localize the leak site.

Methods

Thirty‐six consecutive patients with suspected SIH underwent a standardized total spine MRI protocol, including three‐dimensional HT2‐MRM for SLEC screening at Barnes‐Jewish Hospital/Washington University School of Medicine between December 2023 and November 2025. In 11 SLEC‐positive cases, meso‐CISS was performed for targeted high‐resolution leak localization.

Results

Among the 10 patients with SIH with interpretable meso‐CISS imaging, findings consistent with dural defects were visualized in six (0.5–8 mm in size), with additional supportive features suggestive of dural defects identified in three patients. Compared with HT2‐MRM, meso‐CISS provided higher spatial detail, allowing clearer delineation of dural defects.

Conclusion

A two‐stage spine MRI protocol incorporating HT2‐MRM and meso‐CISS may aid in the noninvasive localization of dural defects in SIH. Meso‐CISS provides high spatial resolution for visualization of small dural defects and associated pathology. Larger studies are required to clarify how this approach may be incorporated into existing diagnostic workflows for spinal CSF leak localization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebrospinal Fluid LeakDura MaterMagnetic Resonance ImagingMagnetic Resonance MyelographyIntracranial HypotensionHumansRetrospective StudiesFemaleMaleMiddle AgedAdultAgedImaging, Three-Dimensional

Stichwörter der Autor:innen

balanced steady‐state free precessioncerebrospinal fluidconstructive interference in steady statemagnetic resonance duragraphymagnetic resonance imagingspine imaging

Autor:innen und Institutionen

  • Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Neurosurgery, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Neurology, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA.

ORCID-Profile: Arash Nazeri

Zitieren

APA

Wegscheid, M. L., Nigogosyan, Z., Chatterjee, A. R., Raji, C. A., Reis, M. N., Fleege, N. P., Azad, S. N., Plog, B. A., Ogunlade, J., Vellimana, A. K., Goyal, M. S., & Nazeri, A. (2026). Mesoscale CISS imaging for the detection of dural defects in spinal CSF leaks: A retrospective case series. Headache: The Journal of Head and Face Pain, 66(7), 1563-1574. https://doi.org/10.1111/head.70123

Vancouver

Wegscheid ML, Nigogosyan Z, Chatterjee AR, Raji CA, Reis MN, Fleege NP, et al. Mesoscale CISS imaging for the detection of dural defects in spinal CSF leaks: A retrospective case series. Headache: The Journal of Head and Face Pain. 2026;66(7):1563-1574. doi:10.1111/head.70123

BibTeX
@article{Wegscheid2026,
  author = {Wegscheid, Michelle L and Nigogosyan, Zack and Chatterjee, Arindam R and Raji, Cyrus A and Reis, Martin N and Fleege, Nicholas P and Azad, Sherwin N and Plog, Benjamin A and Ogunlade, John and Vellimana, Ananth K and Goyal, Manu S and Nazeri, Arash},
  title = {Mesoscale CISS imaging for the detection of dural defects in spinal CSF leaks: A retrospective case series},
  journal = {Headache: The Journal of Head and Face Pain},
  year = {2026},
  volume = {66},
  number = {7},
  pages = {1563--1574},
  doi = {10.1111/head.70123}
}
Kostenlos starten →