Fachartikel in der Zeitschrift Hemodialysis International, online erschienen am 05.07.2026. Verfasst von Lin Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: First College of Clinical Medicine, Shandong University of Traditional Chinese Medicine, Jinan City, Shandong Province, China. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Hemodialysis access thrombosis is the primary cause of access failure. Thrombus removal is an effective strategy to restore access function. Although both open surgical and endovascular procedures enable thrombus clearance, endovascular thrombus reduction therapy is widely adopted in clinical practice for this condition due to its minimally invasive and effective properties.
Methods
We describe a novel separator‐assisted catheter thrombectomy technique for the management of hemodialysis access thrombosis. In this procedure, a large‐bore catheter is used for negative‐pressure thrombus aspiration, with an embolus separator concurrently utilized to disrupt intraluminal thrombus and maintain catheter patency during aspiration.
Results
This approach effectively enhances thrombus clearance efficiency and shortens procedural time. In our reported thrombectomy cases involving arteriovenous fistula (AV fistula), arteriovenous graft (AV graft), and central venous catheters, the SWAM ( S eparator W ith A spirator for M echanical Thrombectomy) technique achieved favorable therapeutic efficacy for acute thrombus and, to a certain extent, for chronic thrombus.
Conclusion
This technique provides a novel therapeutic alternative for the management of hemodialysis access thrombosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- First College of Clinical Medicine, Shandong University of Traditional Chinese Medicine, Jinan City, Shandong Province, China.
- Department of Vascular Surgery Center, Qingdao Hiser Hospital Affiliated of Qingdao University, Qingdao Traditional Chinese Medicine Hospital, Qingdao City, Shandong Province, China.
- Department of Peripheral Vascular Disease, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan City, Shandong Province, China.
ORCID-Profile: Mingdi Zhu, Zheng Liu
Zitieren
APA
Li, L., Zhang, Z., Wang, H., Zhu, M., Wang, K., & Liu, Z. (2026). Utility of the SWAM (Separator With Aspirator for Mechanical Thrombectomy) Device in Managing Hemodialysis Access Thrombosis. Hemodialysis International. https://doi.org/10.1111/hdi.70111
Vancouver
Li L, Zhang Z, Wang H, Zhu M, Wang K, Liu Z. Utility of the SWAM (Separator With Aspirator for Mechanical Thrombectomy) Device in Managing Hemodialysis Access Thrombosis. Hemodialysis International. 2026. doi:10.1111/hdi.70111
BibTeX
@article{Li2026,
author = {Li, Lin and Zhang, Zhongwang and Wang, Hongjie and Zhu, Mingdi and Wang, Kun and Liu, Zheng},
title = {Utility of the SWAM (Separator With Aspirator for Mechanical Thrombectomy) Device in Managing Hemodialysis Access Thrombosis},
journal = {Hemodialysis International},
year = {2026},
doi = {10.1111/hdi.70111}
}
EUVIMED