EUVIMEDEUVIMED entdecken
Crossref

Bedside Placement of Right Internal Jugular Tunneled Dialysis Catheters by Nephrologists Without Fluoroscopy: Safety and Outcomes From a Retrospective Single‐Center Study

Ganesh Srinivasa Prasad P iD, Aravind Sarvepalli iD, Limesh M, Vinod Nagesh, Nitin Kumar Hegde

Hemodialysis International · 2026

DOI: 10.1111/hdi.70097 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hemodialysis International, 2026. Verfasst von Ganesh Srinivasa Prasad P und 4 weiteren Autor:innen. Beteiligte Einrichtung: Mazumdar Shaw Medical Centre, NH Health City, Bangalore, India. Hauptthemen laut MEDLINE: Renal Dialysis, Jugular Veins, Catheterization, Central Venous, Nephrologists. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Guidelines recommend fluoroscopic guidance for tunneled hemodialysis catheter placement, but fluoroscopy is costly, not universally available, and increases patient radiation exposure. Ultrasound‐guided bedside placement by nephrologists, using anatomical landmarks, may provide a safe and cost‐effective alternative. To evaluate the immediate safety and outcomes of nonfluoroscopic right internal jugular vein tunneled catheter placement performed by nephrologists in a tertiary care center.

Methods

Conducted a retrospective analysis of all tunneled dialysis catheters placed bedside at our center between January 2021 and December 2022. Ultrasound was used for venous cannulation, anatomical landmarks for surface marking, and postprocedure chest radiography for tip confirmation. The primary outcome was procedure‐related complications within 24 h. Access failure, defined as the inability to use the catheter for dialysis within 24 h, was the secondary outcome.

Results

Among 235 patients (77.4% male; mean age 55.8 years), 7 (2.9%) developed immediate complications. Minor exit‐site bleeding occurred in four patients (1.7%), all managed conservatively; two received fresh frozen plasma. Catheter malposition occurred in two cases (0.85%); one required repositioning and the other replacement with a femoral catheter. One patient (0.4%) had a cardiac arrest attributed to acute coronary syndrome unrelated to the procedure. Access failure occurred in one case (0.4%). All remaining catheters functioned successfully for immediate dialysis.

Conclusion

Ultrasound‐guided, nonfluoroscopic bedside placement of right internal jugular vein tunneled catheters by nephrologists is feasible, safe, and cost‐effective. This technique reduces radiation exposure and costs, supporting its role in resource‐limited settings. Prospective multicenter studies are warranted to assess long‐term patency, infection rates, and dialysis adequacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisJugular VeinsCatheterization, Central VenousNephrologistsCatheters, IndwellingHumansRetrospective StudiesFemaleMaleMiddle AgedFluoroscopyAgedAdult

Stichwörter der Autor:innen

bedside procedurecomplicationsend stage kidney diseasefluoroscopyhemodialysisnephrologisttunneled dialysis cathetervascular access

Autor:innen und Institutionen

  • Mazumdar Shaw Medical Centre, NH Health City, Bangalore, India.

ORCID-Profile: Ganesh Srinivasa Prasad P, Aravind Sarvepalli

Zitieren

APA

P, G. S. P., Sarvepalli, A., M, L., Nagesh, V., & Hegde, N. K. (2026). Bedside Placement of Right Internal Jugular Tunneled Dialysis Catheters by Nephrologists Without Fluoroscopy: Safety and Outcomes From a Retrospective Single‐Center Study. Hemodialysis International. https://doi.org/10.1111/hdi.70097

Vancouver

P GSP, Sarvepalli A, M L, Nagesh V, Hegde NK. Bedside Placement of Right Internal Jugular Tunneled Dialysis Catheters by Nephrologists Without Fluoroscopy: Safety and Outcomes From a Retrospective Single‐Center Study. Hemodialysis International. 2026. doi:10.1111/hdi.70097

BibTeX
@article{P2026,
  author = {P, Ganesh Srinivasa Prasad and Sarvepalli, Aravind and M, Limesh and Nagesh, Vinod and Hegde, Nitin Kumar},
  title = {Bedside Placement of Right Internal Jugular Tunneled Dialysis Catheters by Nephrologists Without Fluoroscopy: Safety and Outcomes From a Retrospective Single‐Center Study},
  journal = {Hemodialysis International},
  year = {2026},
  doi = {10.1111/hdi.70097}
}
Kostenlos starten →