Comparison between lung ultrasonography and current methods for volume assessment in Asian chronic hemodialysis patients
Hemodialysis International · 2020-10 · 24 (4) · 516-527
DOI: 10.1111/hdi.12871 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hemodialysis International, online erschienen am 18.08.2020. Verfasst von Clara L Y Ngoh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, University Medicine Cluster, National University Hospital, Singapore, Singapore. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Introduction
Volume assessment in end‐stage kidney disease patients on hemodialysis (HD) remains inadequate by existing methods: clinical examination, bioimpedance spectroscopy, measurement of inferior vena cava diameter by ultrasound (IVCD), and plasma B‐type natriuretic peptide (NT‐pro BNP). This study aims to compare the performance of lung ultrasound against existing methods for volume assessment in a HD cohort.
Methods
Two nephrologists independently performed 28‐point lung ultrasound immediately before and after midweek HD in 50 patients. Lung congestion was classified into mild, moderate, and severe categories based on lung ultrasound findings. Clinical examination for crepitations and oedema, change in hydration status (∆HS) measured by bioimpedance spectroscopy, NT‐pro BNP, IVCD during inspiration (IVCDimin), expiration (IVCDimax), and inferior vena cava collapsibility index were also assessed before and after midweek HD.
Findings
In all, 61% of patients with normohydration status by bioimpedance spectroscopy had moderate or severe lung congestion on lung ultrasound. There were significant correlations between predialysis lung ultrasound, and NT‐pro BNP (r = 0.432, P = 0.004), ∆HS (r = 0.447, P < 0.001), and IVCD parameters (P < 0.05). Some correlations weakened postdialysis (∆HS [r = 0.322, P = 0.01] and IVCDimax [r = 0.307, P = 0.03]), whereas NT‐pro BNP and ∆HS paradoxically increased in 28% and 30% of the cohort, respectively. On receiver operator curve analysis, most methods of volume assessment had limited discriminatory power to detect mild lung congestion.
Discussion
Lung ultrasound demonstrates some comparability with existing volume assessment methods in Asian dialysis patients. However, it appears more effective at detecting subclinical pulmonary congestion, and tracking fluid changes real‐time compared to bioimpedance spectroscopy and NT‐pro BNP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Nephrology, University Medicine Cluster, National University Hospital, Singapore, Singapore.
- Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
ORCID-Profile: Clara L Y Ngoh
Zitieren
APA
Ngoh, C. L. Y., Teng, H. L., Chua, Y. T., Leo, C. C. H., & Wong, W. K. (2020). Comparison between lung ultrasonography and current methods for volume assessment in Asian chronic hemodialysis patients. Hemodialysis International, 24(4), 516-527. https://doi.org/10.1111/hdi.12871
Vancouver
Ngoh CLY, Teng HL, Chua YT, Leo CCH, Wong WK. Comparison between lung ultrasonography and current methods for volume assessment in Asian chronic hemodialysis patients. Hemodialysis International. 2020;24(4):516-527. doi:10.1111/hdi.12871
BibTeX
@article{Ngoh2020,
author = {Ngoh, Clara L Y and Teng, Hazel L and Chua, Yan T and Leo, Christopher C H and Wong, Weng K},
title = {Comparison between lung ultrasonography and current methods for volume assessment in Asian chronic hemodialysis patients},
journal = {Hemodialysis International},
year = {2020},
volume = {24},
number = {4},
pages = {516--527},
doi = {10.1111/hdi.12871}
}
EUVIMED