Weight‐Bearing Lunge Test in Young Patients With Haemophilia and Limited Joint Damage: Reliability and Functional Associations for Ankle Assessment
Haemophilia · 2026-07 · 32 (4) · 1042-1048
DOI: 10.1111/hae.70308 ↗Kurz gefasst
Fachartikel in der Zeitschrift Haemophilia, online erschienen am 12.05.2026. Verfasst von Firat Tan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Atatürk University, Erzurum, Türkiye. Hauptthemen laut MEDLINE: Hemophilia A, Weight-Bearing, Ankle Joint. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Performance‐based measures are essential for detecting early musculoskeletal functional limitations in patients with haemophilia (PwH). The Weight‐Bearing Lunge Test (WBLT) assesses ankle dorsiflexion mobility, but its psychometric properties in PwH remain unclear.
Aim
To determine the test–retest reliability and construct validity of the WBLT in young PwH and limited joint damage, and to examine its associations with ankle‐specific clinical and imaging measures.
Methods
This prospective cross‐sectional study included 24 PwH (mean age: 15.6 ± 4.7 years). Ankle dorsiflexion was assessed using the WBLT and tibial inclination angle with Goniometer PRO. Test–retest reliability was evaluated in 20 participants. Joint health was assessed using the HJHS and HEAD‐US. Reliability was analysed using ICC (2,1), and construct validity using Spearman correlations.
Results
The WBLT demonstrated excellent test–retest reliability (ICC = 0.96–0.99). Moderate correlations were found between WBLT Right and HJHS Total Score ( r = −0.493, p = 0.014), HJHS Right Ankle Score ( r = −0.621, p = 0.001), and HEAD‐US Right Ankle Score ( r = −0.481, p = 0.017). WBLT Left correlated with GPRO Left ( r = −0.587, p = 0.006) and HEAD‐US Left Ankle Score ( r = −0.456, p = 0.025). No significant correlations were found with HEAD‐US Total or GPRO Right.
Conclusion
The WBLT showed excellent test–retest reliability and meaningful associations with ankle‐related clinical and imaging findings in young PwH and limited joint damage. These findings suggest that the WBLT may provide a simple, functional, and objective measure of ankle dorsiflexion mobility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Atatürk University, Erzurum, Türkiye.
- Department of Pediatric Hematology, Hacettepe University Faculty of Medicine, Ankara, Türkiye.
- Department of Radiology, Hacettepe University Faculty of Medicine, Ankara, Türkiye.
- Department of Musculoskeletal Physiotherapy and Rehabilitation, Hacettepe University Faculty of Physical Therapy and Rehabilitation, Ankara, Türkiye.
Zitieren
APA
Tan, F., Aytac, S., Yildiz, A. E., & Deniz, H. G. (2026). Weight‐Bearing Lunge Test in Young Patients With Haemophilia and Limited Joint Damage: Reliability and Functional Associations for Ankle Assessment. Haemophilia, 32(4), 1042-1048. https://doi.org/10.1111/hae.70308
Vancouver
Tan F, Aytac S, Yildiz AE, Deniz HG. Weight‐Bearing Lunge Test in Young Patients With Haemophilia and Limited Joint Damage: Reliability and Functional Associations for Ankle Assessment. Haemophilia. 2026;32(4):1042-1048. doi:10.1111/hae.70308
BibTeX
@article{Tan2026,
author = {Tan, Firat and Aytac, Selin and Yildiz, Adalet Elcin and Deniz, Hande Guney},
title = {Weight‐Bearing Lunge Test in Young Patients With Haemophilia and Limited Joint Damage: Reliability and Functional Associations for Ankle Assessment},
journal = {Haemophilia},
year = {2026},
volume = {32},
number = {4},
pages = {1042--1048},
doi = {10.1111/hae.70308}
}
EUVIMED