Fachartikel in der Zeitschrift Haemophilia, 2025. Verfasst von Arman Vahabi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Ege University School of Medicine, Izmir, Turkey. Hauptthemen laut MEDLINE: Hemophilia A, Knee Joint, Joint Diseases, Hemarthrosis. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Various functional and radiological systems have been developed to evaluate joint health and the severity of arthropathy in hemophilic patients. Clinical relevance of these radiological systems has received minimal attention.

Methods

Through a retrospective chart review, 84 patients with end‐stage hemophilic arthropathy of the knee were included. Pettersson and Arnold–Hilgartner scores were assessed by two observers. Correlation between radiological stage and range of motion (ROM), KSS function subscores, KSS pain subscores, total KSS, and surgical time were analyzed.

Results

Interobserver correlation was found to be very strong for Pettersson score, with a value of 0.84 (95% CI: 0.75–0.89) and moderate for the Arnold–Hilgartner with kappa value of 0.4 (95% CI: 0.17–0.62). Correlation between Pettersson score and clinical variables revealed a very weak inverse correlation with ROM ( r = −0.12, 95% CI: −0.33 to 0.10), KSS pain ( r = −0.09, 95% CI: −0.31 to 0.12), and KSS function ( r = −0.16, 95% CI: −0.36 to 0.06), and weak inverse correlation with KSS ( r = −0.24, 95% CI: −0.44 to 0.2). Regarding the correlation between Arnold–Hilgartner score, a weak inverse correlation was observed with ROM ( r = −0.21, 95% CI: −0.41 to 0.00), and very weak inverse correlations with KSS pain ( r = −0.06, 95% CI: −0.16 to 0.27), KSS function ( r = −0.00, 95% CI: −0.22 to 0.21), and KSS ( r = −0.04, 95% CI: −0.25 to 0.18).

Conclusion

Radiologic staging systems demonstrate weak correlation with clinically meaningful variables in patients with end‐stage hemophilic arthropathy of knee, an important consideration in the management of hemophilic arthropathy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hemophilia AKnee JointJoint DiseasesHemarthrosisHumansMaleAdultRetrospective StudiesMiddle AgedRange of Motion, ArticularYoung AdultAdolescentFemaleRadiographySeverity of Illness Index

Stichwörter der Autor:innen

arthroplastybleeding disorderend‐stage arthropathyhemophiliatotal knee replacement

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Ege University School of Medicine, Izmir, Turkey.
  • Department of Orthopaedics and Traumatology, EMOT Hospital, Izmir, Turkey.

ORCID-Profile: Arman Vahabi, Erdem Er, Abdussamet Kuyucu, Elcil Kaya Biçer, Semih Aydoğdu

Zitieren

APA

Vahabi, A., Er, E., Kuyucu, A., Biçer, E. K., & Aydoğdu, S. (2025). Radiological Stage of Hemophilic Arthropathy of Knee Does Not Correlate With Clinical Variables. Haemophilia. https://doi.org/10.1111/hae.70088

Vancouver

Vahabi A, Er E, Kuyucu A, Biçer EK, Aydoğdu S. Radiological Stage of Hemophilic Arthropathy of Knee Does Not Correlate With Clinical Variables. Haemophilia. 2025. doi:10.1111/hae.70088

BibTeX
@article{Vahabi2025,
  author = {Vahabi, Arman and Er, Erdem and Kuyucu, Abdussamet and Biçer, Elcil Kaya and Aydoğdu, Semih},
  title = {Radiological Stage of Hemophilic Arthropathy of Knee Does Not Correlate With Clinical Variables},
  journal = {Haemophilia},
  year = {2025},
  doi = {10.1111/hae.70088}
}
Kostenlos starten →