Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees
Haemophilia · 2024
DOI: 10.1111/hae.15072 ↗Kurz gefasst
Fachartikel in der Zeitschrift Haemophilia, 2024. Verfasst von Arman Vahabi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Ege University School of Medicine, Izmir, Turkey. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Hemophilia A. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
In total knee arthroplasty (TKA), choosing the correct implant size is important. There is lack of data on accuracy of templating on haemophilic knees. Our aim was to test the accuracy of 2D digital templating for TKA on haemophilic arthropathy (HA) of knee. Materials and Methods TKAs performed on HA between January 2011 and January 2022 were screened. Osteoarthritis (OA) group was created as control group by a one‐to‐one matching regarding type of implant used. Intra‐ and interobserver correlations were measured in HA, then correlation between templated and implanted sizes was investigated in four assessments (femur AP, femur lateral, tibia AP, tibia lateral), then compared with OA group. Fifty‐eight knees in each group included.
Results
Regarding intraobserver correlation in HA, there was excellent correlation for femur AP [.93 (.73–.98)], femur lateral [.98 (.91–.99)], and tibia AP (1.0) templating. Regarding interobserver correlation in HA, excellent correlation was observed for femur lateral [.93 (.74–.98)] and tibia AP templating [.90 (.65–.97)]. Regarding correlation of templated and applied sizes in HA; tibia AP, tibia lateral and femur lateral templating showed good correlation [.81 (.70–.89), .86 (.77–.91), .79 (.67–.87) while femur AP templating showed moderate correlation [.67 (.50–.79)]. Comparing HA and OA, there was no difference in correlation levels regarding femur AP, femur lateral, tibia AP and tibia lateral templating ( p = .056, p = .781, p = .761, p = .083, respectively).
Conclusion
Although 2D digital templating shows comparable correlation in HA and OA, clinical applicability of templating on HA appears to be limited in its current state.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Ege University School of Medicine, Izmir, Turkey.
- Department of Orthopaedics and Traumatology, Kars Harakani State Hospital, Kars, Turkey.
- Department of Internal Medicine Division of Hematology, Ege University Faculty of Medicine, Izmir, Turkey.
- Department of Pediatrics Division of Hemato-Oncology, Ege University Faculty of Medicine, Izmir, Turkey.
ORCID-Profile: Arman Vahabi, Kaan Kavakli
Zitieren
APA
Vahabi, A., Er, E., Biçer, E. K., Şahin, F., Kavakli, K., & Aydoğdu, S. (2024). Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees. Haemophilia. https://doi.org/10.1111/hae.15072
Vancouver
Vahabi A, Er E, Biçer EK, Şahin F, Kavakli K, Aydoğdu S. Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees. Haemophilia. 2024. doi:10.1111/hae.15072
BibTeX
@article{Vahabi2024,
author = {Vahabi, Arman and Er, Erdem and Biçer, Elcil Kaya and Şahin, Fahri and Kavakli, Kaan and Aydoğdu, Semih},
title = {Accuracy and clinical role of digital templating for total knee arthroplasty performed on haemophilic knees},
journal = {Haemophilia},
year = {2024},
doi = {10.1111/hae.15072}
}
EUVIMED