30‐sit‐to‐stand power is a better tool than isometric knee extensor strength to detect motor impairment in people with haemophilic arthropathy

Carlos Cruz-Montecinos iD, María Moena-León, Antonio Durán-Ovalle, Aracelli Lizama-Jofré, Verónica Soto, Andrés Oyarzún, Claudio Tapia iD, Sandro R Freitas, Ronei S Pinto, Rodrigo Núñez-Cortés iD, Carla Daffunchio

Haemophilia · 2024

DOI: 10.1111/hae.15021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Haemophilia, 2024. Verfasst von Carlos Cruz-Montecinos und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, Faculty of Medicine, University of Chile, Santiago, Chile. Hauptthemen laut MEDLINE: Isometric Contraction, Hemophilia A, Muscle Strength. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Regular assessment of motor impairments is crucial in people with haemophilic arthropathy (PwHA). This study aimed to determine if there are differences in 30‐seconds sit‐to‐stand (30‐STS) power and maximal voluntary isometric contraction (MVIC) of the knee extensors between PwHA and healthy control group (CG). The secondary aims were to investigate the correlation between 30‐STS power and MVIC of knee extensors with clinical characteristics and to assess their effectiveness in identifying motor impairment in PwHA.

Methods

A cross‐sectional study was conducted by collecting data from PwHA ( n = 17) and a sedentary CG ( n = 15). MVIC (torque) and 30‐STS power were normalised to body mass. Correlation analysis and simple linear regression adjusted for age were used to assess the association between tests and clinical variables. Using z ‐scores derived from the mean and standard deviation of the CG, we compared the MVIC and the 30‐STS power in PwHA.

Results

PwHA showed lower MVIC and 30‐STS power compared to CG ( p < .001; large effect size d > .8). Lower 30‐STS power was associated with greater joint impairment and greater fear of movement, whereas MVIC showed no association with clinical variables. 30‐STS power showed a lower z ‐score compared to MVIC ( p < .001). In addition, 30‐STS power detected 47% of PwHA with motor impairment compared to 0% for MVIC ( p = .002).

Conclusions

Our results suggest that 30‐STS power may be more effective than knee extensors MVIC in detecting motor impairment in PwHA. Consequently, lower limb skeletal muscle power, rather than maximum knee extensor strength, appears to be more affected in PwHA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Isometric ContractionHemophilia AMuscle StrengthHumansMaleAdultCross-Sectional StudiesFemaleYoung AdultMiddle AgedKnee JointKneeJoint DiseasesHemarthrosis

Stichwörter der Autor:innen

haemophiliajoint damagejoint dysfunctionlower limbskeletal muscle function

Autor:innen und Institutionen

  • Department of Physical Therapy, Faculty of Medicine, University of Chile, Santiago, Chile.
  • Research, Innovation, and Development Section in Kinesiology, Kinesiology Unit, San José Hospital, Santiago, Chile.
  • School of Physical Therapy, Faculty of Medicine, University of Chile, Santiago, Chile.
  • Haemophilia Unit, Roberto del Río Hospital, Santiago, Chile.
  • Orthopaedic Surgery Unit, Hospital San Jose, Santiago, Chile, San José Hospital, Santiago, Chile.
  • Neuromuscular Research Lab, Faculdade de Motricidade Humana, Universidade de Lisboa, Cruz Quebrada, Lisboa, Portugal.

ORCID-Profile: Carlos Cruz-Montecinos, Claudio Tapia, Rodrigo Núñez-Cortés

Zitieren

APA

Cruz-Montecinos, C., Moena-León, M., Durán-Ovalle, A., Lizama-Jofré, A., Soto, V., Oyarzún, A., Tapia, C., Freitas, S. R., Pinto, R. S., Núñez-Cortés, R., & Daffunchio, C. (2024). 30‐sit‐to‐stand power is a better tool than isometric knee extensor strength to detect motor impairment in people with haemophilic arthropathy. Haemophilia. https://doi.org/10.1111/hae.15021

Vancouver

Cruz-Montecinos C, Moena-León M, Durán-Ovalle A, Lizama-Jofré A, Soto V, Oyarzún A, et al. 30‐sit‐to‐stand power is a better tool than isometric knee extensor strength to detect motor impairment in people with haemophilic arthropathy. Haemophilia. 2024. doi:10.1111/hae.15021

BibTeX
@article{CruzMontecinos2024,
  author = {Cruz-Montecinos, Carlos and Moena-León, María and Durán-Ovalle, Antonio and Lizama-Jofré, Aracelli and Soto, Verónica and Oyarzún, Andrés and Tapia, Claudio and Freitas, Sandro R and Pinto, Ronei S and Núñez-Cortés, Rodrigo and Daffunchio, Carla},
  title = {30‐sit‐to‐stand power is a better tool than isometric knee extensor strength to detect motor impairment in people with haemophilic arthropathy},
  journal = {Haemophilia},
  year = {2024},
  doi = {10.1111/hae.15021}
}
Kostenlos starten →