Field Evaluation of the Sentinel™ Integrative Passive Sampler for the Measurement of Perfluoroalkyl and Polyfluoroalkyl Substances in Water Using a Modified Organosilica Adsorbent
Groundwater Monitoring & Remediation · 2023-09 · 43 (4) · 38-54
DOI: 10.1111/gwmr.12574 ↗Kurz gefasst
Fachartikel in der Zeitschrift Groundwater Monitoring & Remediation, online erschienen am 19.04.2023. Verfasst von Paul L. Edmiston und 7 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Strategic Environmental Research and Development Program.
Abstract (Originalsprache)
A passive sampler specifically designed to measure perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water was tested in four study areas (Ellsworth and Peterson Air Force bases, CO and SD; the Ohio River, OH, WV, KY, IN; and the Santa Ana River, CA). Locations included both groundwater and surface water locations. Over the 2‐year study, 96 passive samplers were deployed at 33 sample locations and were compared with co‐collected grab samples, all of which were measured for 19 PFAS analytes by HPLC–MS/MS. Correlations were observed (typically within 2× difference) between aqueous PFAS concentrations measured by passive versus discrete grab samples across over 5 orders of magnitude in concentration (0.5 to 150,000 ng/L). Overall relative percent difference between grab and passive results displayed a median of 18% (interquartile range of −19 to 73%). Detection limits were around 1 ng/L for a 2‐week sampling time with sampling rates ranging from 12 to 70 mL/day in flowing systems. Duplicate samplers were deployed in all study areas which indicated a 14 to 42% (median 24%) relative standard deviation in the precision of passive sampling. Larger variances were seen with sites with higher and potentially more variable water flows. A sub‐set of duplicate samplers were measured by a commercial laboratory which returned equivalent data to research laboratory measurements (43 [±26 SD]% relative percent difference). Standardized protocols and calculation methods were developed to facilitate expanded testing and future broader use of passive sampling for PFAS by site investigators.
Förderung
- Strategic Environmental Research and Development Program
Zitieren
APA
Edmiston, P. L., Carter, E., Toth, K., Hershberger, R., Hill, N., Versluis, P., Hollinden, P., & Divine, C. (2023). Field Evaluation of the Sentinel™ Integrative Passive Sampler for the Measurement of Perfluoroalkyl and Polyfluoroalkyl Substances in Water Using a Modified Organosilica Adsorbent. Groundwater Monitoring & Remediation, 43(4), 38-54. https://doi.org/10.1111/gwmr.12574
Vancouver
Edmiston PL, Carter E, Toth K, Hershberger R, Hill N, Versluis P, et al. Field Evaluation of the Sentinel™ Integrative Passive Sampler for the Measurement of Perfluoroalkyl and Polyfluoroalkyl Substances in Water Using a Modified Organosilica Adsorbent. Groundwater Monitoring & Remediation. 2023;43(4):38-54. doi:10.1111/gwmr.12574
BibTeX
@article{Edmiston2023,
author = {Edmiston, Paul L. and Carter, Erika and Toth, Kevin and Hershberger, Riley and Hill, Noah and Versluis, Patrick and Hollinden, Patrick and Divine, Craig},
title = {Field Evaluation of the Sentinel™ Integrative Passive Sampler for the Measurement of Perfluoroalkyl and Polyfluoroalkyl Substances in Water Using a Modified Organosilica Adsorbent},
journal = {Groundwater Monitoring & Remediation},
year = {2023},
volume = {43},
number = {4},
pages = {38--54},
doi = {10.1111/gwmr.12574}
}
EUVIMED