Field Study of Vertical Screening Distance Criteria for Vapor Intrusion of Ethylene Dibromide
Groundwater Monitoring & Remediation · 2022-01 · 42 (1) · 65-80
DOI: 10.1111/gwmr.12484 ↗Kurz gefasst
Fachartikel in der Zeitschrift Groundwater Monitoring & Remediation, online erschienen am 30.10.2021. Verfasst von Ian Hers und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American Petroleum Institute, Chevron, Shell United States.
Abstract (Originalsprache)
Several regulatory agencies recommend screening petroleum vapor intrusion (PVI) sites based on vertical screening distance between a petroleum hydrocarbon source in soil or groundwater and a building foundation. U.S. Environmental Protection Agency (U.S. EPA) indicate the risk of PVI is minimal at buildings that are separated by more than 6 feet (1.8 m) from a dissolved‐phase source and 15 feet (4.6 m) from a light nonaqueous phase liquid (LNAPL) source. This vertical screening distance method is not, however, recommended at sites with leaded gasoline sources containing ethylene dibromide (EDB) because of a lack of field data to document EDB attenuation in the vadose zone. To help address this gap, depth‐discrete soil‐gas samples were collected at a leaded gasoline release site in Sobieski, Minnesota (USA). The maximum concentration of EDB in groundwater (175 μg/L) at the site was high relative to those observed at other leaded gasoline release sites. Soil gas was analyzed for EDB using a modification of U.S. EPA Method TO‐14A that achieved analytical detection limits below the U.S. EPA Vapor Intrusion Screening Level (VISL) for EDB based on a 10 −6 cancer risk (
Förderung
- American Petroleum Institute
- Chevron
- Shell United States
Zitieren
APA
Hers, I., Wilson, J. T., Kolhatkar, R. V., Lahvis, M. A., Luo, E. H., & Jourabchi, P. (2022). Field Study of Vertical Screening Distance Criteria for Vapor Intrusion of Ethylene Dibromide. Groundwater Monitoring & Remediation, 42(1), 65-80. https://doi.org/10.1111/gwmr.12484
Vancouver
Hers I, Wilson JT, Kolhatkar RV, Lahvis MA, Luo EH, Jourabchi P. Field Study of Vertical Screening Distance Criteria for Vapor Intrusion of Ethylene Dibromide. Groundwater Monitoring & Remediation. 2022;42(1):65-80. doi:10.1111/gwmr.12484
BibTeX
@article{Hers2022,
author = {Hers, Ian and Wilson, John T. and Kolhatkar, Ravi V. and Lahvis, Matthew A. and Luo, Emma (Hong) and Jourabchi, Parisa},
title = {Field Study of Vertical Screening Distance Criteria for Vapor Intrusion of Ethylene Dibromide},
journal = {Groundwater Monitoring & Remediation},
year = {2022},
volume = {42},
number = {1},
pages = {65--80},
doi = {10.1111/gwmr.12484}
}