Noble Gas Analyses to Distinguish Between Surface and Subsurface Brine Releases at a Legacy Oil Site
Groundwater · 2024
DOI: 10.1111/gwat.13412 ↗Kurz gefasst
Fachartikel in der Zeitschrift Groundwater, 2024. Verfasst von Daniel C Segal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Chevron Technical Center, 6001 Bollinger Canyon Road, C1348, San Ramon, California, 94583. Hauptthemen laut MEDLINE: Groundwater, Noble Gases, Oil and Gas Fields, Salts. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chevron.
Abstract (Originalsprache)
Attributing the sources of legacy contamination, including brines, is important to determine remediation options and to allocate responsibility. To make sound remediation decisions, it is necessary to distinguish subsurface sources, such as leaking oil and gas (“O&G”) wells or natural upward fluid migrations, from surface releases. While chemical signatures of surface and subsurface releases may be similar, they are expected to imprint specific dissolved noble gas signatures, caused by the accumulation of terrigenic noble gases in subsurface leaks or re‐equilibration of noble gases following surface releases. We demonstrate that only a historic surface release influenced the dissolved noble gas signature of groundwater in monitoring wells contaminated with brine near an abandoned O&G well, rather than subsurface leakage from the well. Elevated brine concentrations were associated with lower terrigenic helium concentrations, indicating re‐equilibration with atmospheric helium at the surface during the release. Geophysical surveying indicating elevated salinity in surficial soils upgradient of the wells further supported the interpretation of the noble gas data. Eliminating the possibility that subsurface leakage was the source of the plume was critical to selecting the proper remedial action at the site, which otherwise may have included an unnecessary and costly well re‐abandonment. This study demonstrates the use of noble gas analysis to compare potential sources of brine contamination in groundwater and to exclude subsurface leakage as a potential source in an oilfield.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Chevron Technical Center, 6001 Bollinger Canyon Road, C1348, San Ramon, California, 94583.
- Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California, 94551-0808.
- Chevron Technical Center, 1400 Smith Street, Houston, Texas, 77002.
Förderung
- Chevron
Zitieren
APA
Segal, D. C., Visser, A., & Bridge, C. (2024). Noble Gas Analyses to Distinguish Between Surface and Subsurface Brine Releases at a Legacy Oil Site. Groundwater. https://doi.org/10.1111/gwat.13412
Vancouver
Segal DC, Visser A, Bridge C. Noble Gas Analyses to Distinguish Between Surface and Subsurface Brine Releases at a Legacy Oil Site. Groundwater. 2024. doi:10.1111/gwat.13412
BibTeX
@article{Segal2024,
author = {Segal, Daniel C and Visser, Ate and Bridge, Cas},
title = {Noble Gas Analyses to Distinguish Between Surface and Subsurface Brine Releases at a Legacy Oil Site},
journal = {Groundwater},
year = {2024},
doi = {10.1111/gwat.13412}
}
EUVIMED