Differences in pulmonary function measured by oscillometry between horses with mild–moderate equine asthma and healthy controls
Equine Veterinary Journal · 2025
DOI: 10.1111/evj.14206 ↗Kurz gefasst
Fachartikel in der Zeitschrift Equine Veterinary Journal, 2025. Verfasst von Chiara Maria Lo Feudo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Equine Sports Medicine Laboratory "Franco Tradati", Department of Veterinary Medicine and Animal Sciences, Università Degli Studi di Milano, Lodi, It…. Hauptthemen laut MEDLINE: Horse Diseases, Oscillometry, Asthma, Respiratory Function Tests. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
The diagnosis of mild–moderate equine asthma (MEA) can be confirmed by airway endoscopy, bronchoalveolar lavage fluid (BALf) cytology, and lung function evaluation by indirect pleural pressure measurement. Oscillometry is a promising pulmonary function test method, but its ability to detect subclinical airway obstruction has been questioned. Objective s To evaluate the differences in lung function measured by oscillometry between healthy and MEA‐affected horses. Study design Prospective case–control clinical study.
Methods
Thirty‐seven horses were divided into healthy and MEA groups, based on history and clinical score; the diagnosis of MEA was confirmed by airway endoscopy and BALf cytology. Horses underwent oscillometry at frequencies ranging from 2 to 6 Hz. Obtained parameters included whole‐breath, inspiratory, expiratory, and the difference between inspiratory and expiratory resistance (Rrs) and reactance (Xrs). Differences between oscillometry parameters at different frequencies were evaluated within and between groups by repeated‐measures two‐way ANOVA and post hoc tests with Bonferroni correction. Frequency dependence was compared between groups by t test. For significant parameters, a receiver operating characteristics curve was designed, cut‐off values were identified and their sensitivity and specificity were calculated. Statistical significance was set at p < 0.05.
Results
No significant differences in Xrs and Rrs were observed between groups. The frequency dependence of whole‐breath and inspiratory Xrs significantly differed between healthy (respectively, −0.03 ± 0.02 and −0.05 ± 0.02 cmH 2 O/L/s) and MEA (−0.1 ± 0.03 and −0.2 ± 0.02 cmH 2 O/L/s) groups ( p < 0.05 and p < 0.01). For inspiratory Xrs frequency dependence, a cut‐off value of −0.06 cmH 2 O/L/s was identified, with 86.4% (95% CI: 66.7%–95.3%) sensitivity and 66.7% (95% CI: 41.7%–84.8%) specificity. Main limitations Sample size, no BALf cytology in some healthy horses.
Conclusions
Oscillometry can represent a useful non‐invasive tool for the diagnosis of MEA. Specifically, the evaluation of the frequency dependence of Xrs may be of special interest.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Equine Sports Medicine Laboratory "Franco Tradati", Department of Veterinary Medicine and Animal Sciences, Università Degli Studi di Milano, Lodi, Italy.
- TechRes Lab, Department of Electronics, Information and Biomedical Engineering, Politecnico di Milano, Milan, Italy.
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, Quebec, Canada.
- Department of Veterinary Medicine, Università degli Studi di Sassari, Sassari, Italy.
ORCID-Profile: Chiara Maria Lo Feudo, Jean-Pierre Lavoie
Zitieren
APA
Lo Feudo, C. M., Ferrucci, F., Bizzotto, D., Dellacà, R., Lavoie, J. P., & Stucchi, L. (2025). Differences in pulmonary function measured by oscillometry between horses with mild–moderate equine asthma and healthy controls. Equine Veterinary Journal. https://doi.org/10.1111/evj.14206
Vancouver
Lo Feudo CM, Ferrucci F, Bizzotto D, Dellacà R, Lavoie JP, Stucchi L. Differences in pulmonary function measured by oscillometry between horses with mild–moderate equine asthma and healthy controls. Equine Veterinary Journal. 2025. doi:10.1111/evj.14206
BibTeX
@article{LoFeudo2025,
author = {Lo Feudo, Chiara Maria and Ferrucci, Francesco and Bizzotto, Davide and Dellacà, Raffaele and Lavoie, Jean-Pierre and Stucchi, Luca},
title = {Differences in pulmonary function measured by oscillometry between horses with mild–moderate equine asthma and healthy controls},
journal = {Equine Veterinary Journal},
year = {2025},
doi = {10.1111/evj.14206}
}