EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ultrasound‐guided caudal cervical articular process arthrocentesis is accurate in live horses with and without arthropathy

Elizabeth J Davidson iD, Darko Stefanovski iD, Joann Slack, Timothy J Manzi

Equine Veterinary Journal · 2025-03 · 57 (2) · 398-405

DOI: 10.1111/evj.14133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Equine Veterinary Journal, online erschienen am 11.07.2024. Verfasst von Elizabeth J Davidson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, University of Pennsylvania, Kennett Square, Pennsylvania, USA. Hauptthemen laut MEDLINE: Horse Diseases, Joint Diseases, Arthrocentesis, Ultrasonography, Interventional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cervical articular process joint (CAPJ) therapy is advocated for horses with neck disorders. Several ultrasound‐guided CAPJ techniques have been described in cadaver studies with 72%–89% intra‐articular injection accuracy; however, the CAPJ injection accuracy in clinical equine practice has not been extensively reported.

Objectives

To describe a modified cranial approach for ultrasound‐guided caudal CAPJ injections, to investigate the accuracy of this CAPJ injection technique in live horses, and to assess the effect of CAPJ injection location, laterality, operator, and radiographic CAPJ enlargement on injection accuracy. Study design Retrospective case study.

Methods

Medical records of adult horses in which ultrasound‐guided caudal (C4–T1) CAPJ injections were performed using a modified cranial approach between November 2006 and December 2020 were reviewed. Radiographic images of caudal cervical vertebrae were assessed by a blinded radiologist and the degree of CAPJ enlargement was graded using a previously described grading system (Rgrade 1‐5b). Ultrasound‐guided caudal CAPJ injection accuracy was determined by synovial fluid retrieval during an individual CAPJ injection. Statistical analysis was performed using mixed‐effects multivariable logistic model to evaluate the association of CAPJ injection accuracy and the CAPJ injection location, Rgrade, laterality (right, left), and operator.

Results

The study included 149 horses with 177 hospital admissions. Synovial fluid was obtained from 586/658 (89.1%) caudal CAPJs using modified cranial ultrasound‐guided approach for CAPJ injections. C6–C7 CAPJ injections had 7‐fold higher likelihood (OR = 6.78, 95% CI: 1.67–27.52; p = 0.007) of synovial fluid retrieval compared with C4–C5 CAPJ injections. Operator, CAPJ injection side (left, right), and degree of radiographic CAPJ enlargement did not have significant effects on the success of synovial fluid retrieval from ultrasound‐guided caudal CAPJ injections. Main limitations Retrospective study design.

Conclusions

Intra‐articular ultrasound‐guided caudal CAPJ injections using a modified cranial approach can be performed accurately in live horses with and without CAPJ arthropathy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Horse DiseasesJoint DiseasesArthrocentesisUltrasonography, InterventionalAnimalsHorsesRetrospective StudiesFemaleInjections, Intra-ArticularMaleCervical Vertebrae

Stichwörter der Autor:innen

arthropathycervical vertebral columnhorse

Autor:innen und Institutionen

  • Department of Clinical Studies, University of Pennsylvania, Kennett Square, Pennsylvania, USA.

ORCID-Profile: Elizabeth J Davidson, Darko Stefanovski

Zitieren

APA

Davidson, E. J., Stefanovski, D., Slack, J., & Manzi, T. J. (2025). Ultrasound‐guided caudal cervical articular process arthrocentesis is accurate in live horses with and without arthropathy. Equine Veterinary Journal, 57(2), 398-405. https://doi.org/10.1111/evj.14133

Vancouver

Davidson EJ, Stefanovski D, Slack J, Manzi TJ. Ultrasound‐guided caudal cervical articular process arthrocentesis is accurate in live horses with and without arthropathy. Equine Veterinary Journal. 2025;57(2):398-405. doi:10.1111/evj.14133

BibTeX
@article{Davidson2025,
  author = {Davidson, Elizabeth J and Stefanovski, Darko and Slack, Joann and Manzi, Timothy J},
  title = {Ultrasound‐guided caudal cervical articular process arthrocentesis is accurate in live horses with and without arthropathy},
  journal = {Equine Veterinary Journal},
  year = {2025},
  volume = {57},
  number = {2},
  pages = {398--405},
  doi = {10.1111/evj.14133}
}
Kostenlos starten →