EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of computed tomographic, radiographic and anatomical dorsal hoof wall measurements

S.‐M. Obitayo, D. Pollard, L. Szabó, A. Nagy

Equine Veterinary Education · 15.07.2026

DOI: 10.1111/eve.70152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Equine Veterinary Education, online erschienen am 15.07.2026. Verfasst von S.‐M. Obitayo und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Nemzeti Kutatási Fejlesztési és Innovációs Hivatal.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

No comparison of radiographic and computed tomographic (CT) dorsal hoof wall (DHW) thickness and DHW to the palmar length of the distal phalanx (DHWDP) ratio has been published. Radiographic measurements obtained with and without radiodense markers on the DHW have not been compared.

Objective

To compare radiographic (±radiodense marker), CT and anatomical measurements of the DHW thickness and DHWDP ratio. Study design Prospective cross‐sectional study.

Methods

Lateromedial radiographs (±radiodense marker on the DHW), midsagittal CT reconstructions and midsagitally cut anatomical specimens were obtained from 31 cadaver limbs. Lateromedial radiographs and CT images of 30 forelimbs of live horses were reviewed. DHW thickness (proximal, middle and distal) and the DHWDP were measured, and the DHWDP ratio was calculated. Measurements of different modalities were compared using the Wilcoxon‐signed rank test, one‐way repeated measures ANOVA or paired t ‐test.

Results

Radiographic measurements were greater than CT measurements at all measurement sites ( n = 60, p < 0.01), for example, middle DHW thickness: median 19.4 mm; interquartile range (IQR) 17.9, 20.6 mm vs. 15.6 mm; 14.6, 16.8 mm. In cadaver limbs ( n = 21), radiographic (middle DHW thickness: mean 19.5 ± standard deviation 2.1 mm) measurements were greater than both CT (16.3 ± 1.8 mm) and anatomical (16.9 ± 2.1 mm) measurements ( p < 0.01). Radiographic (0.27 ± 0.03), CT (0.26 ± 0.04) and anatomical (0.28 ± 0.04) DHWDP ratios differed ( p < 0.01). Using a marker resulted in marginally greater proximal (median 20.8; IQR 19.8, 22.1 vs. 20.3; 18.7, 21.9) and middle (19.9; 18.8, 22.0 vs. 19.5; 18.5, 21.7) radiographic DHW measurements ( n = 31, p < 0.01). Main limitations The position of reference images on different modalities might not have been identical.

Conclusions

Radiographic measurements were greater than CT; thus, radiographic reference ranges for DHW thickness cannot be applied to CT studies. The difference was smaller for DHWDP ratios than for DHW measurements. Using a marker on the DHW results in clinically insignificant overestimation of DHW thickness.

Förderung

  • Nemzeti Kutatási Fejlesztési és Innovációs Hivatal

Zitieren

APA

Obitayo, S., Pollard, D., Szabó, L., & Nagy, A. (2026). Comparison of computed tomographic, radiographic and anatomical dorsal hoof wall measurements. Equine Veterinary Education. https://doi.org/10.1111/eve.70152

Vancouver

Obitayo S, Pollard D, Szabó L, Nagy A. Comparison of computed tomographic, radiographic and anatomical dorsal hoof wall measurements. Equine Veterinary Education. 2026. doi:10.1111/eve.70152

BibTeX
@article{Obitayo2026,
  author = {Obitayo, S.‐M. and Pollard, D. and Szabó, L. and Nagy, A.},
  title = {Comparison of computed tomographic, radiographic and anatomical dorsal hoof wall measurements},
  journal = {Equine Veterinary Education},
  year = {2026},
  doi = {10.1111/eve.70152}
}
Kostenlos starten →