EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Magnetoencephalographic detection of the epileptic activity localized in the hippocampus using stereotactic electroencephalography and magnetoencephalography simultaneously

Akitake Okamura iD, Akira Hashizume, Kota Kagawa, Go Seyama, Atsuo Yoshino, Shigeto Yamawaki, Nobutaka Horie, Koji Iida

Epilepsia · 2025

DOI: 10.1111/epi.18486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epilepsia, 2025. Verfasst von Akitake Okamura und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Hiroshima University Hospital, Hiroshima, Japan. Hauptthemen laut MEDLINE: Magnetoencephalography, Hippocampus, Electroencephalography, Epilepsy, Temporal Lobe. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Science and Technology Agency (JST), Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the ability of magnetoencephalography (MEG) to detect the activity of a deep brain structure, particularly the hippocampus, using simultaneous stereotactic electroencephalography (SEEG) and MEG recordings.

Methods

We included six patients with intractable temporal lobe epilepsy who underwent simultaneous SEEG and MEG. We recorded SEEG spikes and examined the MEG waveforms. We defined S‐MEG spikes as MEG spikes synchronized with SEEG spikes in the deep brain structures. We examined the proportion of S‐MEG spikes relative to SEEG spikes, the amplitude of S‐MEG spikes, and the signal‐to‐noise ratio (SNR). We also examined the relationship between the spread of epileptic activity and the SNR of S‐MEG spikes. We used SEEG spike‐indexed averaging to improve the SNR and visualize the source of the S‐MEG spikes.

Results

We recorded 1630 SEEG spikes, of which 575 (35.3%) were identified as S‐MEG spikes. The mean amplitude of the S‐MEG spikes derived from hippocampal spikes was 163 femtotesla per centimeter (fT/cm), significantly lower than the amplitude from spikes of cortical tissue ( p < .001). The mean SNR of S‐MEG spikes derived from hippocampal spikes was 0.96, significantly lower than that of cortical tissue spikes ( p < .001). The mean SNR of S‐MEG spikes derived from hippocampal interelectrode synchronized SEEG spikes was 1.09, significantly greater than the mean SNR of 0.92 without interelectrode synchronization ( p = .0035). SEEG spike‐indexed averaging could improve the poor SNR and depict dipoles in the hippocampi. Significance We detected MEG spikes localized in the hippocampus, the amplitude and SNR of which were significantly lower than those of spikes originating from the cortex. As it spreads, hippocampal epileptic activity becomes easier to detect with MEG, but it remains challenging for MEG to improve the poor SNR to detect the limited hippocampal activity without SEEG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetoencephalographyHippocampusElectroencephalographyEpilepsy, Temporal LobeStereotaxic TechniquesDrug Resistant EpilepsyHumansMaleFemaleAdultMiddle AgedYoung AdultSignal-To-Noise Ratio

Stichwörter der Autor:innen

epilepsyhippocampusmagnetoencephalographysimultaneous recordingstereotactic electroencephalography

Autor:innen und Institutionen

  • Department of Neurosurgery, Hiroshima University Hospital, Hiroshima, Japan.
  • Center for Brain, Mind and KANSEI Science Research, Hiroshima University, Hiroshima, Japan.
  • Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Epilepsy Center, Hiroshima University Hospital, Hiroshima, Japan.

ORCID-Profile: Akitake Okamura

Förderung

  • Japan Science and Technology Agency (JST)
  • Japan Society for the Promotion of Science

Zitieren

APA

Okamura, A., Hashizume, A., Kagawa, K., Seyama, G., Yoshino, A., Yamawaki, S., Horie, N., & Iida, K. (2025). Magnetoencephalographic detection of the epileptic activity localized in the hippocampus using stereotactic electroencephalography and magnetoencephalography simultaneously. Epilepsia. https://doi.org/10.1111/epi.18486

Vancouver

Okamura A, Hashizume A, Kagawa K, Seyama G, Yoshino A, Yamawaki S, et al. Magnetoencephalographic detection of the epileptic activity localized in the hippocampus using stereotactic electroencephalography and magnetoencephalography simultaneously. Epilepsia. 2025. doi:10.1111/epi.18486

BibTeX
@article{Okamura2025,
  author = {Okamura, Akitake and Hashizume, Akira and Kagawa, Kota and Seyama, Go and Yoshino, Atsuo and Yamawaki, Shigeto and Horie, Nobutaka and Iida, Koji},
  title = {Magnetoencephalographic detection of the epileptic activity localized in the hippocampus using stereotactic electroencephalography and magnetoencephalography simultaneously},
  journal = {Epilepsia},
  year = {2025},
  doi = {10.1111/epi.18486}
}
Kostenlos starten →