Validation of a discrete electrographic seizure detection algorithm for extended‐duration, reduced‐channel wearable EEG
Epilepsia · 2025-07 · 66 (7) · 2433-2443
DOI: 10.1111/epi.18365 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Epilepsia, online erschienen am 19.03.2025. Verfasst von Tyler J Newton und 9 weiteren Autor:innen. Beteiligte Einrichtung: Epitel, Salt Lake City, Utah, USA. Hauptthemen laut MEDLINE: Algorithms, Electroencephalography, Wearable Electronic Devices, Seizures. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, NINDS NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Objective
Reduced‐channel wearable electroencephalography (EEG) may overcome the accessibility and patient comfort limitations of traditional ambulatory electrographic seizure monitoring during extended‐duration use. Automated algorithms are necessary for review of extended‐duration reduced‐channel EEG, yet current clinical support software is designed only for full‐montage recordings.
Methods
The performance of a novel automated seizure detection algorithm for reduced‐channel EEG (Epitel) was evaluated in a clinical validation study involving 50 participants (31 with seizures) with diverse demographic and seizure representation.
Results
The algorithm demonstrated an event‐level sensitivity of 86.2% (95% confidence interval [CI] = 79.5%–93.2%) and a false detection rate of .162 per hour (95% CI = .116–.221), which is comparable to the performance of current clinical software for full‐montage EEG. Performance varied by electrographic seizure type, with 91.4% sensitivity for focal evolving to generalized seizures, 86.7% for generalized seizures, and 77.3% for focal seizures. The algorithm maintained robust performance in both pediatric participants aged 6–21 years (83% sensitivity) and adults aged 22+ years (90% sensitivity), as well as in ambulatory (80%) and epilepsy monitoring unit (EMU) monitoring environments (87.5%). The false detection rate in ambulatory monitoring environments (.290 false positive [FP] detections/h), all of which involved pediatric participants, was notably higher than in the EMU (.136 FP/h), indicating an area with clear need for improvement for unrestricted at‐home monitoring. The algorithm's supplemental Confidence metric, designed to engender trust in the algorithm, showed a strong correlation with detection precision. Significance These results suggest that this algorithm can provide crucial support for review of extended‐duration reduced‐channel wearable EEG, enabling electrographic seizure monitoring with no restrictions on a person's daily life.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Epitel, Salt Lake City, Utah, USA.
- Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital & Harvard Medical School, Boston, Massachusetts, USA.
- Epilepsy Section, Department of Neurology, University of Colorado, Aurora, Colorado, USA.
- Department of Neurology, New York University Grossman School of Medicine, NYU Langone Health, New York, New York, USA.
ORCID-Profile: Tyler J Newton
Förderung
- NIH HHS
- NINDS NIH HHS
- National Institutes of Health
Zitieren
APA
Newton, T. J., Frankel, M. A., Tosi, Z., Kazen, A. B., Muvvala, V. K., Loddenkemper, T., Spitz, M. C., Strom, L., Friedman, D., & Lehmkuhle, M. J. (2025). Validation of a discrete electrographic seizure detection algorithm for extended‐duration, reduced‐channel wearable EEG. Epilepsia, 66(7), 2433-2443. https://doi.org/10.1111/epi.18365
Vancouver
Newton TJ, Frankel MA, Tosi Z, Kazen AB, Muvvala VK, Loddenkemper T, et al. Validation of a discrete electrographic seizure detection algorithm for extended‐duration, reduced‐channel wearable EEG. Epilepsia. 2025;66(7):2433-2443. doi:10.1111/epi.18365
BibTeX
@article{Newton2025,
author = {Newton, Tyler J and Frankel, Mitchell A and Tosi, Zoë and Kazen, Avidor B and Muvvala, Vamshi K and Loddenkemper, Tobias and Spitz, Mark C and Strom, Laura and Friedman, Daniel and Lehmkuhle, Mark J},
title = {Validation of a discrete electrographic seizure detection algorithm for extended‐duration, reduced‐channel wearable EEG},
journal = {Epilepsia},
year = {2025},
volume = {66},
number = {7},
pages = {2433--2443},
doi = {10.1111/epi.18365}
}
EUVIMED