Generalizability of electroencephalographic interpretation using artificial intelligence: An external validation study
Epilepsia · 2024-10 · 65 (10) · 3028-3037
DOI: 10.1111/epi.18082 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Epilepsia, online erschienen am 14.08.2024. Verfasst von Daniel Mansilla und 9 weiteren Autor:innen. Beteiligte Einrichtung: Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Electroencephalography, Artificial Intelligence. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: CIHR, Duke University, Canadian Institutes of Health Research.
Abstract (Originalsprache)
Objective
The automated interpretation of clinical electroencephalograms (EEGs) using artificial intelligence (AI) holds the potential to bridge the treatment gap in resource‐limited settings and reduce the workload at specialized centers. However, to facilitate broad clinical implementation, it is essential to establish generalizability across diverse patient populations and equipment. We assessed whether SCORE‐AI demonstrates diagnostic accuracy comparable to that of experts when applied to a geographically different patient population, recorded with distinct EEG equipment and technical settings.
Methods
We assessed the diagnostic accuracy of a “fixed‐and‐frozen” AI model, using an independent dataset and external gold standard, and benchmarked it against three experts blinded to all other data. The dataset comprised 50% normal and 50% abnormal routine EEGs, equally distributed among the four major classes of EEG abnormalities (focal epileptiform, generalized epileptiform, focal nonepileptiform, and diffuse nonepileptiform). To assess diagnostic accuracy, we computed sensitivity, specificity, and accuracy of the AI model and the experts against the external gold standard.
Results
We analyzed EEGs from 104 patients (64 females, median age = 38.6 [range = 16–91] years). SCORE‐AI performed equally well compared to the experts, with an overall accuracy of 92% (95% confidence interval [CI] = 90%–94%) versus 94% (95% CI = 92%–96%). There was no significant difference between SCORE‐AI and the experts for any metric or category. SCORE‐AI performed well independently of the vigilance state (false classification during awake: 5/41 [12.2%], false classification during sleep: 2/11 [18.2%]; p = .63) and normal variants (false classification in presence of normal variants: 4/14 [28.6%], false classification in absence of normal variants: 3/38 [7.9%]; p = .07). Significance SCORE‐AI achieved diagnostic performance equal to human experts in an EEG dataset independent of the development dataset, in a geographically distinct patient population, recorded with different equipment and technical settings than the development dataset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Analytical Neurophysiology Lab, Montreal Neurological Institute and Hospital, Montreal, Quebec, Canada.
- Neurophysiology Unit, Institute of Neurosurgery Dr. Asenjo, Santiago, Chile.
- Holberg EEG, Bergen, Norway.
- Department of Neurology, Duke University Medical Center, Durham, North Carolina, USA.
- Epilepsy Unit, Department of Neurology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
- Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
ORCID-Profile: Daniel Mansilla, Tamir Avigdor, Sándor Beniczky, Birgit Frauscher
Förderung
- CIHR
- Duke University
- Canadian Institutes of Health Research
Zitieren
APA
Mansilla, D., Tveit, J., Aurlien, H., Avigdor, T., Ros-Castello, V., Ho, A., Abdallah, C., Gotman, J., Beniczky, S., & Frauscher, B. (2024). Generalizability of electroencephalographic interpretation using artificial intelligence: An external validation study. Epilepsia, 65(10), 3028-3037. https://doi.org/10.1111/epi.18082
Vancouver
Mansilla D, Tveit J, Aurlien H, Avigdor T, Ros-Castello V, Ho A, et al. Generalizability of electroencephalographic interpretation using artificial intelligence: An external validation study. Epilepsia. 2024;65(10):3028-3037. doi:10.1111/epi.18082
BibTeX
@article{Mansilla2024,
author = {Mansilla, Daniel and Tveit, Jesper and Aurlien, Harald and Avigdor, Tamir and Ros-Castello, Victoria and Ho, Alyssa and Abdallah, Chifaou and Gotman, Jean and Beniczky, Sándor and Frauscher, Birgit},
title = {Generalizability of electroencephalographic interpretation using artificial intelligence: An external validation study},
journal = {Epilepsia},
year = {2024},
volume = {65},
number = {10},
pages = {3028--3037},
doi = {10.1111/epi.18082}
}
EUVIMED