Automated detection of tonic seizures using wearable movement sensor and artificial neural network
Epilepsia · 2024
DOI: 10.1111/epi.18077 ↗Kurz gefasst
Fachartikel in der Zeitschrift Epilepsia, 2024. Verfasst von Sidsel Armand Larsen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neurophysiology, Danish Epilepsy Center, Dianalund, Denmark. Hauptthemen laut MEDLINE: Neural Networks, Computer, Wearable Electronic Devices, Seizures. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Although several validated wearable devices are available for detection of generalized tonic–clonic seizures, automated detection of tonic seizures is still a challenge. In this phase 1 study, we report development and validation of an artificial neural network (ANN) model for automated detection of tonic seizures with visible clinical manifestation using a wearable wristband movement sensor (accelerometer and gyroscope). The dataset prospectively recorded for this study included 70 tonic seizures from 15 patients (seven males, age 3–46 years, median = 19 years). We trained an ANN model to detect tonic seizures. The independent test dataset comprised nocturnal recordings, including 10 tonic seizures from three patients and additional (distractor) data from three subjects without seizures. The ANN model detected nocturnal tonic seizures with visible clinical manifestation with a sensitivity of 100% (95% confidence interval = 69%–100%) and with an average false alarm rate of .16/night. The mean detection latency was 14.1 s (median = 10 s), with a maximum of 47 s. These data suggest that nocturnal tonic seizures can be reliably detected with movement sensors using ANN. Large‐scale, multicenter prospective (phase 3) trials are needed to provide compelling evidence for the clinical utility of this device and detection algorithm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Neurophysiology, Danish Epilepsy Center, Dianalund, Denmark.
- Department of Clinical Medicine, Aarhus University and Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark.
- Danish Care Technology, Sorø, Denmark.
ORCID-Profile: Sándor Beniczky
Zitieren
APA
Larsen, S. A., Johansen, D. H., & Beniczky, S. (2024). Automated detection of tonic seizures using wearable movement sensor and artificial neural network. Epilepsia. https://doi.org/10.1111/epi.18077
Vancouver
Larsen SA, Johansen DH, Beniczky S. Automated detection of tonic seizures using wearable movement sensor and artificial neural network. Epilepsia. 2024. doi:10.1111/epi.18077
BibTeX
@article{Larsen2024,
author = {Larsen, Sidsel Armand and Johansen, Daniel Højrup and Beniczky, Sándor},
title = {Automated detection of tonic seizures using wearable movement sensor and artificial neural network},
journal = {Epilepsia},
year = {2024},
doi = {10.1111/epi.18077}
}
EUVIMED