Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies
Epilepsia · 2024-07 · 65 (7) · 1868-1878
DOI: 10.1111/epi.18002 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Epilepsia, online erschienen am 09.05.2024. Verfasst von Shasha Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University of Chicago, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Electrocorticography, Subdural Space. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Intracranial electroencephalographic (IEEG) recording, using subdural electrodes (SDEs) and stereoelectroencephalography (SEEG), plays a pivotal role in localizing the epileptogenic zone (EZ). SDEs, employed for superficial cortical seizure foci localization, provide information on two‐dimensional seizure onset and propagation. In contrast, SEEG, with its three‐dimensional sampling, allows exploration of deep brain structures, sulcal folds, and bihemispheric networks. SEEG offers the advantages of fewer complications, better tolerability, and coverage of sulci. Although both modalities allow electrical stimulation, SDE mapping can tessellate cortical gyri, providing the opportunity for a tailored resection. With SEEG, both superficial gyri and deep sulci can be stimulated, and there is a lower risk of afterdischarges and stimulation‐induced seizures. Most systematic reviews and meta‐analyses have addressed the comparative effectiveness of SDEs and SEEG in localizing the EZ and achieving seizure freedom, although discrepancies persist in the literature. The combination of SDEs and SEEG could potentially overcome the limitations inherent to each technique individually, better delineating seizure foci. This review describes the strengths and limitations of SDE and SEEG recordings, highlighting their unique indications in seizure localization, as evidenced by recent publications. Addressing controversies in the perceived usefulness of the two techniques offers insights that can aid in selecting the most suitable IEEG in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, University of Chicago, Chicago, Illinois, USA.
- Department of Pediatrics, University of Chicago, Chicago, Illinois, USA.
- Department of Neurological Surgery, University of Chicago, Chicago, Illinois, USA.
ORCID-Profile: Shasha Wu, Hiba A Haider
Zitieren
APA
Wu, S., Issa, N. P., Rose, S. L., Haider, H. A., Nordli, D. R., Towle, V. L., Warnke, P. C., & Tao, J. X. (2024). Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies. Epilepsia, 65(7), 1868-1878. https://doi.org/10.1111/epi.18002
Vancouver
Wu S, Issa NP, Rose SL, Haider HA, Nordli DR, Towle VL, et al. Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies. Epilepsia. 2024;65(7):1868-1878. doi:10.1111/epi.18002
BibTeX
@article{Wu2024,
author = {Wu, Shasha and Issa, Naoum P and Rose, Sandra L and Haider, Hiba A and Nordli, Douglas R and Towle, Vernon L and Warnke, Peter C and Tao, James X},
title = {Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies},
journal = {Epilepsia},
year = {2024},
volume = {65},
number = {7},
pages = {1868--1878},
doi = {10.1111/epi.18002}
}