EUVIMEDEUVIMED entdecken
Open Access

Minimum clinical utility standards for wearable seizure detectors: A simulation study

Daniel M Goldenholz iD, Philippa J Karoly iD, Pedro F Viana iD, Ewan Nurse iD, Tobias Loddenkemper, Andreas Schulze-Bonhage iD, Solveig Vieluf, Elisa Bruno iD, Mona Nasseri, Mark P Richardson iD, Benjamin H Brinkmann iD, M Brandon Westover

Epilepsia · 2024-04 · 65 (4) · 1017-1028

DOI: 10.1111/epi.17917 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epilepsia, online erschienen am 17.02.2024. Verfasst von Daniel M Goldenholz und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Sudden Unexpected Death in Epilepsy, Epilepsy, Wearable Electronic Devices, Epilepsy, Generalized. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NCATS NIH HHS, NIA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Epilepsy management employs self‐reported seizure diaries, despite evidence of seizure underreporting. Wearable and implantable seizure detection devices are now becoming more widely available. There are no clear guidelines about what levels of accuracy are sufficient. This study aimed to simulate clinical use cases and identify the necessary level of accuracy for each.

Methods

Using a realistic seizure simulator (CHOCOLATES), a ground truth was produced, which was then sampled to generate signals from simulated seizure detectors of various capabilities. Five use cases were evaluated: (1) randomized clinical trials (RCTs), (2) medication adjustment in clinic, (3) injury prevention, (4) sudden unexpected death in epilepsy (SUDEP) prevention, and (5) treatment of seizure clusters. We considered sensitivity (0%–100%), false alarm rate (FAR; 0–2/day), and device type (external wearable vs. implant) in each scenario.

Results

The RCT case was efficient for a wide range of wearable parameters, though implantable devices were preferred. Lower accuracy wearables resulted in subtle changes in the distribution of patients enrolled in RCTs, and therefore higher sensitivity and lower FAR values were preferred. In the clinic case, a wide range of sensitivity, FAR, and device type yielded similar results. For injury prevention, SUDEP prevention, and seizure cluster treatment, each scenario required high sensitivity and yet was minimally influenced by FAR. Significance The choice of use case is paramount in determining acceptable accuracy levels for a wearable seizure detection device. We offer simulation results for determining and verifying utility for specific use case and specific wearable parameters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sudden Unexpected Death in EpilepsyEpilepsyWearable Electronic DevicesEpilepsy, GeneralizedHumansSeizuresElectroencephalography

Stichwörter der Autor:innen

SUDEPclinical trialcomputationinjuryseizure clustersimulationwearable electronic devices

Autor:innen und Institutionen

  • Department of Neurology, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Neurology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
  • Department of Neurology, University of Melbourne, Melbourne, Victoria, Australia.
  • School of Neuroscience, Institute of Psychiatry, Psychology, and Neuroscience, King's College London, London, UK.
  • Faculty of Medicine, University of Lisbon, Lisbon, Portugal.
  • Seer Medical, Melbourne, Victoria, Australia.

ORCID-Profile: Daniel M Goldenholz, Philippa J Karoly, Pedro F Viana, Ewan Nurse, Andreas Schulze-Bonhage, Elisa Bruno, Mark P Richardson, Benjamin H Brinkmann

Förderung

  • NINDS NIH HHS
  • NCATS NIH HHS
  • NIA NIH HHS
  • NHLBI NIH HHS
  • National Institute of Neurological Disorders and Stroke
  • Division of Chemical, Bioengineering, Environmental, and Transport Systems
  • National Science Foundation
  • Epilepsy Foundation

Zitieren

APA

Goldenholz, D. M., Karoly, P. J., Viana, P. F., Nurse, E., Loddenkemper, T., Schulze-Bonhage, A., Vieluf, S., Bruno, E., Nasseri, M., Richardson, M. P., Brinkmann, B. H., & Westover, M. B. (2024). Minimum clinical utility standards for wearable seizure detectors: A simulation study. Epilepsia, 65(4), 1017-1028. https://doi.org/10.1111/epi.17917

Vancouver

Goldenholz DM, Karoly PJ, Viana PF, Nurse E, Loddenkemper T, Schulze-Bonhage A, et al. Minimum clinical utility standards for wearable seizure detectors: A simulation study. Epilepsia. 2024;65(4):1017-1028. doi:10.1111/epi.17917

BibTeX
@article{Goldenholz2024,
  author = {Goldenholz, Daniel M and Karoly, Philippa J and Viana, Pedro F and Nurse, Ewan and Loddenkemper, Tobias and Schulze-Bonhage, Andreas and Vieluf, Solveig and Bruno, Elisa and Nasseri, Mona and Richardson, Mark P and Brinkmann, Benjamin H and Westover, M Brandon},
  title = {Minimum clinical utility standards for wearable seizure detectors: A simulation study},
  journal = {Epilepsia},
  year = {2024},
  volume = {65},
  number = {4},
  pages = {1017--1028},
  doi = {10.1111/epi.17917}
}
Kostenlos starten →