EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Semiautomated electric source imaging determines epileptogenicity of encephaloceles in temporal lobe epilepsy

Dorin-Cristian Antal iD, Dirk-Matthias Altenmüller iD, Matthias Dümpelmann iD, Christian Scheiwe, Peter C Reinacher, Eliza-Theona Crihan, Bogdan-Emilian Ignat, Iulian-Dan Cuciureanu, Theo Demerath iD, Horst Urbach iD, Andreas Schulze-Bonhage iD, Marcel Heers iD

Epilepsia · 2024-03 · 65 (3) · 651-663

DOI: 10.1111/epi.17879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epilepsia, online erschienen am 23.01.2024. Verfasst von Dorin-Cristian Antal und 11 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Epilepsy Center, Medical Center-University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Epilepsy, Temporal Lobe. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

We aimed to assess the ability of semiautomated electric source imaging (ESI) from long‐term video‐electroencephalographic (EEG) monitoring (LTM) to determine the epileptogenicity of temporopolar encephaloceles (TEs) in patients with temporal lobe epilepsy.

Methods

We conducted a retrospective study involving 32 temporal lobe epilepsy patients with TEs as potentially epileptogenic lesions in structural magnetic resonance imaging scans. Findings were validated through invasive intracerebral stereo‐EEG in six of 32 patients and postsurgical outcome after tailored resection of the TE in 17 of 32 patients. LTM (mean duration = 6 days) was performed using the 10/20 system with additional T1/T2 for all patients and sphenoidal electrodes in 23 of 32 patients. Semiautomated detection and clustering of interictal epileptiform discharges (IEDs) were carried out to create IED types. ESI was performed on the averages of the two most frequent IED types per patient, utilizing individual head models, and two independent inverse methods (sLORETA [standardized low‐resolution brain electromagnetic tomography], MUSIC [multiple signal classification]). ESI maxima concordance and propagation in spatial relation to TEs were quantified for sources with good signal quality (signal‐to‐noise ratio > 2, explained signal > 60%).

Results

ESI maxima correctly colocalized with a TE in 20 of 32 patients (62.5%) either at the onset or half‐rising flank of at least one IED type per patient. ESI maxima showed propagation from the temporal pole to other temporal or extratemporal regions in 14 of 32 patients (44%), confirming propagation originating in the area of the TE. The findings from both inverse methods validated each other in 14 of 20 patients (70%), and sphenoidal electrodes exhibited the highest signal amplitudes in 17 of 23 patients (74%). The concordance of ESI with the TE predicted a seizure‐free postsurgical outcome (Engel I vs. >I) with a diagnostic odds ratio of 2.1. Significance Semiautomated ESI from LTM often successfully identifies the epileptogenicity of TEs and the IED onset zone within the area of the TEs. Additionally, it shows potential predictive power for postsurgical outcomes in these patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Epilepsy, Temporal LobeHumansElectroencephalographyEncephaloceleRetrospective StudiesTemporal LobeMagnetic Resonance Imaging

Stichwörter der Autor:innen

electric source imagingencephaloceleepilepsy surgerymagnetic resonance imagingtemporal lobe epilepsy

Autor:innen und Institutionen

  • Faculty of Medicine, Epilepsy Center, Medical Center-University of Freiburg, Freiburg, Germany.
  • Neurology Clinic, Rehabilitation Clinical Hospital, Iași, Romania.
  • I Neurology Clinic, "Prof. Dr. N. Oblu" Emergency Clinical Hospital, Iasi, Romania.
  • University of Medicine and Pharmacy "Grigore T. Popa", Iasi, Romania.
  • Department of Neurosurgery, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Department of Stereotactic and Functional Neurosurgery, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

ORCID-Profile: Dorin-Cristian Antal, Dirk-Matthias Altenmüller, Matthias Dümpelmann, Theo Demerath, Horst Urbach, Andreas Schulze-Bonhage, Marcel Heers

Zitieren

APA

Antal, D. C., Altenmüller, D. M., Dümpelmann, M., Scheiwe, C., Reinacher, P. C., Crihan, E. T., Ignat, B. E., Cuciureanu, I. D., Demerath, T., Urbach, H., Schulze-Bonhage, A., & Heers, M. (2024). Semiautomated electric source imaging determines epileptogenicity of encephaloceles in temporal lobe epilepsy. Epilepsia, 65(3), 651-663. https://doi.org/10.1111/epi.17879

Vancouver

Antal DC, Altenmüller DM, Dümpelmann M, Scheiwe C, Reinacher PC, Crihan ET, et al. Semiautomated electric source imaging determines epileptogenicity of encephaloceles in temporal lobe epilepsy. Epilepsia. 2024;65(3):651-663. doi:10.1111/epi.17879

BibTeX
@article{Antal2024,
  author = {Antal, Dorin-Cristian and Altenmüller, Dirk-Matthias and Dümpelmann, Matthias and Scheiwe, Christian and Reinacher, Peter C and Crihan, Eliza-Theona and Ignat, Bogdan-Emilian and Cuciureanu, Iulian-Dan and Demerath, Theo and Urbach, Horst and Schulze-Bonhage, Andreas and Heers, Marcel},
  title = {Semiautomated electric source imaging determines epileptogenicity of encephaloceles in temporal lobe epilepsy},
  journal = {Epilepsia},
  year = {2024},
  volume = {65},
  number = {3},
  pages = {651--663},
  doi = {10.1111/epi.17879}
}
Kostenlos starten →