Fachartikel in der Zeitschrift Epilepsia, online erschienen am 25.10.2023. Verfasst von Shuang Yu und 12 weiteren Autor:innen. Beteiligte Einrichtung: IBM Australia, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Epilepsy, Wearable Electronic Devices. Die Arbeit wurde bisher 64-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: German Research Foundation, IBM Research, Epilepsy Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Wrist‐ or ankle‐worn devices are less intrusive than the widely used electroencephalographic (EEG) systems for monitoring epileptic seizures. Using custom‐developed deep‐learning seizure detection models, we demonstrate the detection of a broad range of seizure types by wearable signals.

Methods

Patients admitted to the epilepsy monitoring unit were enrolled and asked to wear wearable sensors on either wrists or ankles. We collected patients' electrodermal activity, accelerometry (ACC), and photoplethysmography, from which blood volume pulse (BVP) is derived. Board‐certified epileptologists determined seizure onset, offset, and types using video and EEG recordings per the International League Against Epilepsy 2017 classification. We applied three neural network models—a convolutional neural network (CNN) and a CNN–long short‐term memory (LSTM)‐based generalized detection model and an autoencoder‐based personalized detection model—to the raw time‐series sensor data to detect seizures and utilized performance measures, including sensitivity, false positive rate (the number of false alarms divided by the total number of nonseizure segments), number of false alarms per day, and detection delay. We applied a 10‐fold patientwise cross‐validation scheme to the multisignal biosensor data and evaluated model performance on 28 seizure types.

Results

We analyzed 166 patients (47.6% female, median age = 10.0 years) and 900 seizures (13 254 h of sensor data) for 28 seizure types. With a CNN‐LSTM‐based seizure detection model, ACC, BVP, and their fusion performed better than chance; ACC and BVP data fusion reached the best detection performance of 83.9% sensitivity and 35.3% false positive rate. Nineteen of 28 seizure types could be detected by at least one data modality with area under receiver operating characteristic curve > .8 performance. Significance Results from this in‐hospital study contribute to a paradigm shift in epilepsy care that entails noninvasive seizure detection, provides time‐sensitive and accurate data on additional clinical seizure types, and proposes a novel combination of an out‐of‐the‐box monitoring algorithm with an individualized person‐oriented seizure detection approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EpilepsyWearable Electronic DevicesHumansFemaleChildMaleArtificial IntelligenceSeizuresAlgorithmsElectroencephalography

Stichwörter der Autor:innen

deep learningepilepsyseizure detectionseizureswearables

Autor:innen und Institutionen

  • IBM Australia, Melbourne, Victoria, Australia.
  • Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Digital Health, IBM T. J. Watson Research Center, Yorktown Heights, New York, USA.
  • Digital Health Cooperative Research Centre, Melbourne, Victoria, Australia.

ORCID-Profile: Shuang Yu, Rima El Atrache, Jianbin Tang, Michele Jackson, Theodore Sheehan, Solveig Vieluf, Stefan Harrer, Tobias Loddenkemper

Förderung

  • German Research Foundation
  • IBM Research
  • Epilepsy Research Fund
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Yu, S., El Atrache, R., Tang, J., Jackson, M., Makarucha, A., Cantley, S., Sheehan, T., Vieluf, S., Zhang, B., Rogers, J. L., Mareels, I., Harrer, S., & Loddenkemper, T. (2023). Artificial intelligence‐enhanced epileptic seizure detection by wearables. Epilepsia, 64(12), 3213-3226. https://doi.org/10.1111/epi.17774

Vancouver

Yu S, El Atrache R, Tang J, Jackson M, Makarucha A, Cantley S, et al. Artificial intelligence‐enhanced epileptic seizure detection by wearables. Epilepsia. 2023;64(12):3213-3226. doi:10.1111/epi.17774

BibTeX
@article{Yu2023,
  author = {Yu, Shuang and El Atrache, Rima and Tang, Jianbin and Jackson, Michele and Makarucha, Adam and Cantley, Sarah and Sheehan, Theodore and Vieluf, Solveig and Zhang, Bo and Rogers, Jeffrey L and Mareels, Iven and Harrer, Stefan and Loddenkemper, Tobias},
  title = {Artificial intelligence‐enhanced epileptic seizure detection by wearables},
  journal = {Epilepsia},
  year = {2023},
  volume = {64},
  number = {12},
  pages = {3213--3226},
  doi = {10.1111/epi.17774}
}
Kostenlos starten →