EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

Automated detection of absence seizures using a wearable electroencephalographic device: a phase 3 validation study and feasibility of automated behavioral testing

Giorgi Japaridze, Dirk Loeckx, Tim Buckinx, Sidsel Armand Larsen, Renée Proost, Katrien Jansen, Paul MacMullin, Natalia Paiva, Sofia Kasradze, Alexander Rotenberg, Lieven Lagae iD, Sándor Beniczky iD

Epilepsia · 2023-12 · 64 (S4)

DOI: 10.1111/epi.17200 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Epilepsia, online erschienen am 13.03.2022. Verfasst von Giorgi Japaridze und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Neurology and Neuropsychology, Tbilisi, Georgia. Hauptthemen laut MEDLINE: Epilepsy, Absence, Wearable Electronic Devices. Die Arbeit wurde bisher 53-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Epilepsy Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Our primary goal was to measure the accuracy of fully automated absence seizure detection, using a wearable electroencephalographic (EEG) device. As a secondary goal, we also tested the feasibility of automated behavioral testing triggered by the automated detection.

Methods

We conducted a phase 3 clinical trial (NCT04615442), with a prospective, multicenter, blinded study design. The input was the one‐channel EEG recorded with dry electrodes embedded into a wearable headband device connected to a smartphone. The seizure detection algorithm was developed using artificial intelligence (convolutional neural networks). During the study, the predefined algorithm, with predefined cutoff value, analyzed the EEG in real time. The gold standard was derived from expert evaluation of simultaneously recorded full‐array video‐EEGs. In addition, we evaluated the patients' responsiveness to the automated alarms on the smartphone, and we compared it with the behavioral changes observed in the clinical video‐EEGs.

Results

We recorded 102 consecutive patients (57 female, median age = 10 years) on suspicion of absence seizures. We recorded 364 absence seizures in 39 patients. Device deficiency was 4.67%, with a total recording time of 309 h. Average sensitivity per patient was 78.83% (95% confidence interval [CI] = 69.56%–88.11%), and median sensitivity was 92.90% (interquartile range [IQR] = 66.7%–100%). The average false detection rate was .53/h (95% CI = .32–.74). Most patients ( n = 66, 64.71%) did not have any false alarms. The median F1 score per patient was .823 (IQR = .57–1). For the total recording duration, F1 score was .74. We assessed the feasibility of automated behavioral testing in 36 seizures; it correctly documented nonresponsiveness in 30 absence seizures, and responsiveness in six electrographic seizures. Significance Automated detection of absence seizures with a wearable device will improve seizure quantification and will promote assessment of patients in their home environment. Linking automated seizure detection to automated behavioral testing will provide valuable information from wearable devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Epilepsy, AbsenceWearable Electronic DevicesHumansFemaleChildArtificial IntelligenceFeasibility StudiesProspective StudiesSeizuresAlgorithmsElectroencephalography

Stichwörter der Autor:innen

absence seizureartificial intelligenceautomated detectionbehavioral testingepilepsywearable devices

Autor:innen und Institutionen

  • Institute of Neurology and Neuropsychology, Tbilisi, Georgia.
  • Epihunter, Hasselt, Belgium.
  • Department of Clinical Neurophysiology, Danish Epilepsy Center Filadelfia, Dianalund, Denmark.
  • University of Leuven, Leuven, Belgium.
  • Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Clinical Neurophysiology, Aarhus University Hospital, and Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

ORCID-Profile: Lieven Lagae, Sándor Beniczky

Förderung

  • Epilepsy Foundation

Zitieren

APA

Japaridze, G., Loeckx, D., Buckinx, T., Armand Larsen, S., Proost, R., Jansen, K., MacMullin, P., Paiva, N., Kasradze, S., Rotenberg, A., Lagae, L., & Beniczky, S. (2023). Automated detection of absence seizures using a wearable electroencephalographic device: a phase 3 validation study and feasibility of automated behavioral testing. Epilepsia, 64(S4). https://doi.org/10.1111/epi.17200

Vancouver

Japaridze G, Loeckx D, Buckinx T, Armand Larsen S, Proost R, Jansen K, et al. Automated detection of absence seizures using a wearable electroencephalographic device: a phase 3 validation study and feasibility of automated behavioral testing. Epilepsia. 2023;64(S4). doi:10.1111/epi.17200

BibTeX
@article{Japaridze2023,
  author = {Japaridze, Giorgi and Loeckx, Dirk and Buckinx, Tim and Armand Larsen, Sidsel and Proost, Renée and Jansen, Katrien and MacMullin, Paul and Paiva, Natalia and Kasradze, Sofia and Rotenberg, Alexander and Lagae, Lieven and Beniczky, Sándor},
  title = {Automated detection of absence seizures using a wearable electroencephalographic device: a phase 3 validation study and feasibility of automated behavioral testing},
  journal = {Epilepsia},
  year = {2023},
  volume = {64},
  number = {S4},
  doi = {10.1111/epi.17200}
}
Kostenlos starten →