EUVIMEDEUVIMED entdecken
Crossref

3D Printed Guides and Finite Element Analysis in Dental Autotransplantation: Biomechanical Efficiency and Clinical Workflow Optimization

Junzhou Chi iD, Lu Yin, Shaozhen Ma, Xin Yang, Maoyuan Zhang, Xiaohua Ren, Kun Tian

Dental Traumatology · 2026

DOI: 10.1111/edt.13087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental Traumatology, 2026. Verfasst von Junzhou Chi und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Stomatology, Southwest Medical University, Luzhou, China. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Finite Element Analysis, Osteotomy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Natural Science Foundation of Sichuan Province, the Key Research and Development Project of Chengdu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study evaluates novel osteotomy guides, a morphology‐adapted custom drill, and root‐immersion containers to enhance the precision in dental autotransplantation through in vitro experiments and finite element analysis (FEA).

Methods

About 30 mandibular Cone Beam Computed Tomography (CBCT) datasets were reconstructed to design reverse‐engineered osteotomy guides and a steel custom drill based on root morphology statistics. About 90 3D‐printed models (30 cases × 3 groups: guide‐assisted, custom drill, and freehand) underwent socket preparation, with operative time and cavity dimensions quantified via optical scanning. Extracorporeal root canal treatment compared between teeth in root‐immersion containers (n=30) and handheld teeth (n=30). FEA simulated flexible/rigid fixation to assess the apical stress and displacement.

Results

(1) Osteotomy time was shortest with the custom drill (3.70 ± 0.42 min), followed by guided (5.33 ± 0.35 min) and freehand (12.18 ± 0.98 min; p < 0.001). (2) Root‐socket distances were 0.58 ± 0.10 mm (custom drill) and 0.94 ± 0.12 mm (guided), outperforming freehand (1.75 ± 0.19 mm; p < 0.001). (3) Root canal duration was comparable between container (13.77 ± 0.78 min) and handheld (13.89 ± 1.12 min; p > 0.05), but procedural consistency favored the container ( p < 0.001). (4) Rigid splinting reduced apical stress and limited displacement to 1.2 mm versus 3–5 mm with flexible methods.

Conclusion

The custom drill achieved efficient socket preparation with superior root adaptation, while the root‐immersion container standardized therapy quality. Rigid fixation minimized biomechanical risks, collectively ensuring predictable autotransplantation outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalFinite Element AnalysisOsteotomyHumansCone-Beam Computed TomographyBiomechanical PhenomenaTransplantation, AutologousWorkflowTooth SocketMandibleTooth Root

Stichwörter der Autor:innen

3D printingautologous tooth transplantationcustom drillfinite element analysisroot‐immersion containers

Autor:innen und Institutionen

  • School of Stomatology, Southwest Medical University, Luzhou, China.
  • Department of Stomatology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, China.

ORCID-Profile: Junzhou Chi

Förderung

  • Natural Science Foundation of Sichuan Province
  • the Key Research and Development Project of Chengdu

Zitieren

APA

Chi, J., Yin, L., Ma, S., Yang, X., Zhang, M., Ren, X., & Tian, K. (2026). 3D Printed Guides and Finite Element Analysis in Dental Autotransplantation: Biomechanical Efficiency and Clinical Workflow Optimization. Dental Traumatology. https://doi.org/10.1111/edt.13087

Vancouver

Chi J, Yin L, Ma S, Yang X, Zhang M, Ren X, et al. 3D Printed Guides and Finite Element Analysis in Dental Autotransplantation: Biomechanical Efficiency and Clinical Workflow Optimization. Dental Traumatology. 2026. doi:10.1111/edt.13087

BibTeX
@article{Chi2026,
  author = {Chi, Junzhou and Yin, Lu and Ma, Shaozhen and Yang, Xin and Zhang, Maoyuan and Ren, Xiaohua and Tian, Kun},
  title = {3D Printed Guides and Finite Element Analysis in Dental Autotransplantation: Biomechanical Efficiency and Clinical Workflow Optimization},
  journal = {Dental Traumatology},
  year = {2026},
  doi = {10.1111/edt.13087}
}
Kostenlos starten →