EUVIMEDEUVIMED entdecken
Kontrollierte klinische StudieOpen Access · CC BY 4.0

Clinical Efficacy of CBCT and 3D‐Printed Replicas in Molar Autotransplantation: A Controlled Clinical Trial

Miks Lejnieks iD, Ilze Akota iD, Gundega Jākobsone iD, Laura Neimane iD, Sergio E Uribe iD

Dental Traumatology · 2025-04 · 41 (2) · 161-170

DOI: 10.1111/edt.13012 ↗

Kurz gefasst

Kontrollierte klinische Studie in der Zeitschrift Dental Traumatology, online erschienen am 06.11.2024. Verfasst von Miks Lejnieks und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery and Oral Medicine, Riga Stradins University, Riga, Latvia. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Printing, Three-Dimensional, Molar, Third, Molar. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Latvijas Zinātnes Padome, IEVA Project, HORIZON EUROPE Framework Programme, Latvijas Zinātnes Padome.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Aim To evaluate the efficacy of the combined cone‐beam (CBCT)/3D‐replicas protocol on the clinical and radiographic outcomes of autotransplanted molars. Material and Methods Controlled clinical trial registered ISRCTN13563091 from August 2019 to September 2022. Patients aged 13–22 years requiring permanent premolar extraction and having at least one non‐erupted third molar were enrolled at the Institute of Stomatology, Stradins University, Riga, Latvia. Patients in the 3D‐replicas ( n = 30) underwent maxillary CBCT scans and had 3D‐printed replicas of the third molar fabricated, while the control group ( n = 28) did not. The clinical outcomes included tooth mobility, bleeding on probing, and periodontal pocket depth assessed at 3, 6, and 12 months. The radiographic outcomes included root development, obliteration, periapical status, and crown changes at 12 months.

Results

Of the 55 patients assigned to interventions, 46 completed the study. No significant differences in survival and radiographic outcomes were found between the control ( n = 22) and 3D‐replica group ( n = 24): root development ( p = 0.3), root resorption ( p = 0.057), periapical status ( p = 0.7), and crown/root ratio change ( p = 0.4). Logistic regression showed no significant associations between radiologic predictors (root resorption: p = 0.4; periapical status: p > 0.9; root development: p = 0.8). Significant clinical outcome predictors included total operative time ( β = 0.0043, p = 0.049), Moorrees' stage (stage 4: β = −0.31, p < 0.001; stage 5: β = −0.39, p < 0.001), and four donor placement times ( β = 0.93, p < 0.001), but group assignment was not a significant predictor.

Conclusions

The CBCT/3D‐replica protocol showed no significant differences in the clinical or radiological outcomes. The high success rates in both groups suggest that the protocol is valuable primarily for optimizing surgical efficiency and as a training tool for clinicians.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyPrinting, Three-DimensionalMolar, ThirdMolarHumansAdolescentFemaleMaleYoung AdultTransplantation, AutologousTreatment OutcomeTooth Extraction

Stichwörter der Autor:innen

cone beam computed tomographyimmatureprinted tooth replicathird molartooth transplantation

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery and Oral Medicine, Riga Stradins University, Riga, Latvia.
  • Baltic Biomaterials Centre of Excellence, Headquarters at Riga Technical University, Riga, Latvia.
  • Institute of Stomatology, Riga Stradins University, Riga, Latvia.
  • Institute of Stomatology Implantology Clinic, Riga Stradins University, Riga, Latvia.
  • Department of Orthodontics, Riga Stradins University, Riga, Latvia.
  • Department of Conservative Dentistry and Oral Health, Riga Stradins University, Riga, Latvia.

ORCID-Profile: Miks Lejnieks, Ilze Akota, Gundega Jākobsone, Laura Neimane, Sergio E Uribe

Förderung

  • Latvijas Zinātnes Padome, IEVA Project
  • HORIZON EUROPE Framework Programme
  • Latvijas Zinātnes Padome

Zitieren

APA

Lejnieks, M., Akota, I., Jākobsone, G., Neimane, L., & Uribe, S. E. (2025). Clinical Efficacy of CBCT and 3D‐Printed Replicas in Molar Autotransplantation: A Controlled Clinical Trial. Dental Traumatology, 41(2), 161-170. https://doi.org/10.1111/edt.13012

Vancouver

Lejnieks M, Akota I, Jākobsone G, Neimane L, Uribe SE. Clinical Efficacy of CBCT and 3D‐Printed Replicas in Molar Autotransplantation: A Controlled Clinical Trial. Dental Traumatology. 2025;41(2):161-170. doi:10.1111/edt.13012

BibTeX
@article{Lejnieks2025,
  author = {Lejnieks, Miks and Akota, Ilze and Jākobsone, Gundega and Neimane, Laura and Uribe, Sergio E},
  title = {Clinical Efficacy of CBCT and 3D‐Printed Replicas in Molar Autotransplantation: A Controlled Clinical Trial},
  journal = {Dental Traumatology},
  year = {2025},
  volume = {41},
  number = {2},
  pages = {161--170},
  doi = {10.1111/edt.13012}
}
Kostenlos starten →