Effect of 3D printed replicas on the duration of third molar autotransplantation surgery: A controlled clinical trial
Dental Traumatology · 2024-04 · 40 (2) · 221-228
DOI: 10.1111/edt.12905 ↗Kurz gefasst
Kontrollierte klinische Studie in der Zeitschrift Dental Traumatology, 2023-11. Verfasst von Miks Lejnieks und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery and Oral Medicine, Riga Stradins University, Riga, Latvia. Hauptthemen laut MEDLINE: Molar, Molar, Third. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: European Commission.
Abstract (Originalsprache)
Background/Aim This study aimed to develop a protocol that combines cone‐beam computed tomography (CBCT), software, and 3D printing to design 3D replicas for tooth autotransplantation. The goal was to evaluate the impact of this approach on the extraoral time of the donor teeth and the total surgical time, thereby enhancing surgical efficiency and outcomes. Materials and Methods A non‐randomized trial (protocol 10.1186/ISRCTN13563091 ) was conducted at Riga Stradins University, enrolling 46 patients (13–22 years old) who required molar extraction and possessed a non‐erupted third molar. The patients were sequentially assigned to a 3D replica group (24 patients) or a control group (22 patients). The primary outcome measured was the extra‐alveolar time of the donor tooth, and the secondary outcome was the total duration of surgery. Both were assessed using a sample size capable of detecting a 10‐min difference. A generalized linear model adjusted for various factors was used to test for significant time differences ( p < .05) between the groups.
Results
Forty‐six patients were included in this analysis. The effect of using 3D replicas was not statistically significant and was associated with a decrease in the extraoral time of the donor tooth in seconds ( β = −9.35, 95% CI [−40.86, 22.16]). For the total surgical time in minutes, the use of 3D replicas had a statistically significant impact, reducing the operation duration in minutes ( β = −13.42, 95% CI [−24.50, −2.34]). No early complications were observed in either group, with all teeth present at 3–4 weeks post‐surgery.
Conclusions
The integration of 3D printing technology can enhance the efficiency of autotransplantation surgeries, primarily by reducing surgical time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Riga Stradins University, Riga, Latvia.
- Baltic Biomaterials Centre of Excellence, Headquarters at Riga Technical University, Riga, Latvia.
- Department of Orthodontics, Riga Stradins University, Riga, Latvia.
- Department of Conservative Dentistry and Oral Health, Riga Stradins University, Riga, Latvia.
- School of Dentistry, Universidad Austral de Chile, Valdivia, Chile.
ORCID-Profile: Miks Lejnieks, Ilze Akota, Gundega Jākobsone, Laura Neimane, Oskars Radzins, Sergio E Uribe
Förderung
- European Commission
Zitieren
APA
Lejnieks, M., Akota, I., Jākobsone, G., Neimane, L., Radzins, O., & Uribe, S. E. (2024). Effect of 3D printed replicas on the duration of third molar autotransplantation surgery: A controlled clinical trial. Dental Traumatology, 40(2), 221-228. https://doi.org/10.1111/edt.12905
Vancouver
Lejnieks M, Akota I, Jākobsone G, Neimane L, Radzins O, Uribe SE. Effect of 3D printed replicas on the duration of third molar autotransplantation surgery: A controlled clinical trial. Dental Traumatology. 2024;40(2):221-228. doi:10.1111/edt.12905
BibTeX
@article{Lejnieks2024,
author = {Lejnieks, Miks and Akota, Ilze and Jākobsone, Gundega and Neimane, Laura and Radzins, Oskars and Uribe, Sergio E},
title = {Effect of 3D printed replicas on the duration of third molar autotransplantation surgery: A controlled clinical trial},
journal = {Dental Traumatology},
year = {2024},
volume = {40},
number = {2},
pages = {221--228},
doi = {10.1111/edt.12905}
}
EUVIMED