Preprocedural assessment of coronary artery disease in patients undergoing transcatheter aortic valve implantation: Rationale and design of the EASE‐IT CT registry
European Journal of Clinical Investigation · 2024
DOI: 10.1111/eci.14274 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Journal of Clinical Investigation, 2024. Verfasst von Julia Mascherbauer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine 3, University Hospital St. Pölten, Karl Landsteiner University of Health Sciences, Krems, Austria. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Registries, Aortic Valve Stenosis, Coronary Artery Disease. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Invasive coronary angiography (ICA) is the standard for pre‐procedural assessment of coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI). However, it requires hospitalization and can be associated with complications. Computed tomography angiography (CTA) may be a viable alternative to rule out prognostically relevant CAD.
Methods
The EASE‐IT CT Registry is an investigator‐initiated, prospective, observational, multicentre pilot registry involving patients aged ≥75 years with severe aortic stenosis (AS) intended to implant a transcatheter heart valve (THV) of the SAPIEN family. A total of 150 patients will be recruited from four sites in Germany and Austria. The registry will consist of two prospective cohorts: the investigational CTA‐only cohort and the CTA + ICA control cohort. The CTA‐only cohort will enrol 100 patients in whom significant (≥50%) left main (LM) and/or proximal left anterior descending artery (LAD) stenosis are ruled out on CTA. The CTA + ICA control cohort will enrol 50 patients who have undergone both CTA and ICA before TAVI and in whom ≥50% LM/proximal LAD stenosis has been ruled out by CTA. Three composite endpoints will be assessed at 3 months post‐TAVI: CAD‐specific endpoints, VARC‐3‐defined device success and early safety.
Conclusion
The EASE‐IT CT Registry evaluates whether TAVI can be carried out safely without performing ICA if prognostically relevant CAD of the LM/proximal LAD is ruled out with CTA. If so, the omission of ICA would help streamline the pre‐procedural workup of TAVI patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine 3, University Hospital St. Pölten, Karl Landsteiner University of Health Sciences, Krems, Austria.
- Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany.
- Department of Cardiology and Angiology, BG University Hospital Bergmannsheil Bochum, Ruhr university, Bochum, Germany.
- Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Centre, North Rhine-Westphalia, University Hospital, Ruhr-University Bochum, Bad Oeynhausen, Germany.
- Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, Vienna, Austria.
- Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany.
ORCID-Profile: Peter Bramlage
Zitieren
APA
Mascherbauer, J., Rudolph, T., Strauch, J. T., Seiffert, M., Bleiziffer, S., Bartko, P. E., Zielinski, M., Vijayan, A., Bramlage, P., & Hengstenberg, C. (2024). Preprocedural assessment of coronary artery disease in patients undergoing transcatheter aortic valve implantation: Rationale and design of the EASE‐IT CT registry. European Journal of Clinical Investigation. https://doi.org/10.1111/eci.14274
Vancouver
Mascherbauer J, Rudolph T, Strauch JT, Seiffert M, Bleiziffer S, Bartko PE, et al. Preprocedural assessment of coronary artery disease in patients undergoing transcatheter aortic valve implantation: Rationale and design of the EASE‐IT CT registry. European Journal of Clinical Investigation. 2024. doi:10.1111/eci.14274
BibTeX
@article{Mascherbauer2024,
author = {Mascherbauer, Julia and Rudolph, Tanja and Strauch, Justus T and Seiffert, Moritz and Bleiziffer, Sabine and Bartko, Philipp Emanuel and Zielinski, Marie and Vijayan, Anjaly and Bramlage, Peter and Hengstenberg, Christian},
title = {Preprocedural assessment of coronary artery disease in patients undergoing transcatheter aortic valve implantation: Rationale and design of the EASE‐IT CT registry},
journal = {European Journal of Clinical Investigation},
year = {2024},
doi = {10.1111/eci.14274}
}
EUVIMED