Atrial fibrillation and QT corrected. What is the best formula to use?
European Journal of Clinical Investigation · 2023-09 · 53 (9)
DOI: 10.1111/eci.14013 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Clinical Investigation, online erschienen am 12.05.2023. Verfasst von Francesco Luzza und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Background
QT interval varies with the heart rate (HR), so a correction in QT calculation is needed (QTc). Atrial fibrillation (AF) is associated with elevated HR and beat‐to‐beat variation.
Aim
To find best correlation between QTc in atrial fibrillation (AF) versus restored sinus rhytm (SR) after electrical cardioversion (ECV) (primary end point) and to determine which correction formula and method are the best to determine QTc in AF (secondary end point).
Methods
During a 3‐month period, we considered patients who underwent 12‐lead ECG recording and received an AF diagnosis with indication for ECV. Exclusion criteria were as follows: QRS duration >120 ms, therapy with QT‐prolonging drugs, a rate control strategy and a nonelectrical cardioversion. The QT interval was corrected using Bazzett's, Framingham, Fridericia and Hodges formulas during the last ECG during AF and the first one immediately after ECV. QTc mean was calculated as mQTc (average of 10 QTc calculated beat per beat) and as QTcM (QTc calculated from the average of 10 raw QT and RR for each beat).
Results
Fifty consecutive patients were enrolled in the study. Bazett's formula showed a significant change in mean QTc value between the two rhythms (421.5 ± 33.9 vs. 446.1 ± 31.9; p < 0.001 for mQTc and 420.9 ± 34.1 vs. 441.8 ± 30.9; p = 0.003 for QTcM). On the contrary, in patients with SR, QTc assessed by the Framingham, Fridericia, and Hodges formulas was similar to that in AF. Furthermore, good correlations between mQTc and QTcM are present for each formula, even in AF or SR.
Conclusions
During AF, Bazzett's formula, seems to be the most imprecise in QTc estimation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy.
- Operative Unit of ICCU and Cardiology, Hospital "S. Maria della Misericordia", Urbino, Italy.
- Cardiothoracic Department, Policlinico Riuniti University Hospital, Foggia, Italy.
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Section of Cardiology, University of Messina, Messina, Italy.
ORCID-Profile: Francesca Campanella, Michele Correale
Zitieren
APA
Luzza, F., De Sarro, R., Licordari, R., Crea, P., Pugliatti, P., Certo, G., Pistelli, L., Campanella, F., Lo Nigro, M. C., Casale, M., Correale, M., & Dattilo, G. (2023). Atrial fibrillation and QT corrected. What is the best formula to use?. European Journal of Clinical Investigation, 53(9). https://doi.org/10.1111/eci.14013
Vancouver
Luzza F, De Sarro R, Licordari R, Crea P, Pugliatti P, Certo G, et al. Atrial fibrillation and QT corrected. What is the best formula to use?. European Journal of Clinical Investigation. 2023;53(9). doi:10.1111/eci.14013
BibTeX
@article{Luzza2023,
author = {Luzza, Francesco and De Sarro, Rosalba and Licordari, Roberto and Crea, Pasquale and Pugliatti, Pietro and Certo, Giuseppe and Pistelli, Lorenzo and Campanella, Francesca and Lo Nigro, Maria Claudia and Casale, Matteo and Correale, Michele and Dattilo, Giuseppe},
title = {Atrial fibrillation and QT corrected. What is the best formula to use?},
journal = {European Journal of Clinical Investigation},
year = {2023},
volume = {53},
number = {9},
doi = {10.1111/eci.14013}
}
EUVIMED