Left Atrial Volume and Strain by Two‐Dimensional Versus Three‐Dimensional Echocardiography in Healthy Subjects: Reference Values are Not Interchangeable
Echocardiography · 2026-06 · 43 (6)
DOI: 10.1111/echo.70538 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Echocardiography, online erschienen am 23.06.2026. Verfasst von Lei Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Wuxi No. 2 People's Hospital, Wuxi, China. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Heart Atria, Atrial Function, Left, Echocardiography. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Background
Little is known about the differences in left atrial (LA) volume and strain assessed with two‐dimensional (2DE) and three‐dimensional echocardiography(3DE). Therefore, this study aimed to compare 2DE and 3DE parameters in healthy subjects.
Methods
We obtained LA volumes and strains by 3DE and 2DE in 328 healthy subjects (52 ± 13 years; 51.83% men).
Results
Means of 3DE LA volume indexes (LAVIs) were higher than those derived from 2DE (maximal LAVI: 26.75 vs. 22.66 mL/m 2 ; minimal LAVI: 11.76 vs. 9.30 mL/m 2 ; preA LAVI: 19.52 vs. 16.23 mL/m 2 , respectively, all p < 0.001). Conversely, means of 3DE LA phasic strains were lower than those derived from 2DE (LA reservoir strain: 25.16 vs. 32.01%; LA conduit strain: 13.09 vs. 16.52%; LA contractile strain: 12.12 vs. 15.52%, respectively, all p < 0.001). Similarly, total, passive, and active LA emptying fractions (EF) were lower with 3DE than those with 2DE (all p < 0.05). Correlation between 3DE and 2DE was moderate for LAVIs (all r > 0.65, all p < 0.001), with 2DE showing a systematic underestimation (bias: −4.09 mL/m 2 for maximal LAVI; −2.46 mL/m 2 for minimal LAVI, −3.30 mL/m 2 for preA LAVI). For LA strain parameters, only conduit strain showed moderate correlation ( r = 0.65, p < 0.001) with an overestimation bias of +3.42%, while reservoir and contractile strains correlated poorly between modalities with wide limits of agreement. LAEFs also demonstrated poor inter‐modality agreement.
Conclusions
2DE yielded lower LAVIs but higher LA strain and EF values compared to 3DE. Although there was a significant correlation between the 2D and 3D parameters, agreement analysis indicated that their normal reference values were not interchangeable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Wuxi No. 2 People's Hospital, Wuxi, China.
- Department of Cardiology, Jiangnan University Medical Center, Wuxi, China.
Zitieren
APA
Li, L., You, C., Yan, X., & Jin, Y. (2026). Left Atrial Volume and Strain by Two‐Dimensional Versus Three‐Dimensional Echocardiography in Healthy Subjects: Reference Values are Not Interchangeable. Echocardiography, 43(6). https://doi.org/10.1111/echo.70538
Vancouver
Li L, You C, Yan X, Jin Y. Left Atrial Volume and Strain by Two‐Dimensional Versus Three‐Dimensional Echocardiography in Healthy Subjects: Reference Values are Not Interchangeable. Echocardiography. 2026;43(6). doi:10.1111/echo.70538
BibTeX
@article{Li2026,
author = {Li, Lei and You, Chunyuan and Yan, Xiaoyang and Jin, Yan},
title = {Left Atrial Volume and Strain by Two‐Dimensional Versus Three‐Dimensional Echocardiography in Healthy Subjects: Reference Values are Not Interchangeable},
journal = {Echocardiography},
year = {2026},
volume = {43},
number = {6},
doi = {10.1111/echo.70538}
}