Three‐dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure
Echocardiography · 2024
DOI: 10.1111/echo.15822 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Echocardiography, 2024. Verfasst von Sima Narimani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Echocardiography, Three-Dimensional, Heart Septal Defects, Atrial, Septal Occluder Device. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Tehran Heart Center.
Abstract (Originalsprache)
Background
Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three‐dimensional transesophageal echocardiography (3D‐TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D–TEE to those utilizing the standard balloon sizing method.
Methods
We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop‐flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D‐TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed.
Results
Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D‐TEE images multi‐planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D‐images data and BS in round or oval‐shaped ASDs.
Conclusion
The 3D‐TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D‐TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D‐TEE measurements in guiding the best treatment decisions for ASD closure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
- Department of Advanced Echocardiography, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
ORCID-Profile: Aryan Ayati
Förderung
- Tehran Heart Center
Zitieren
APA
Narimani, S., Ayati, A., Tayebi, A., Jalai, A., Amirsardari, Z., Sahebjam, M., & Zoroufian, A. (2024). Three‐dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure. Echocardiography. https://doi.org/10.1111/echo.15822
Vancouver
Narimani S, Ayati A, Tayebi A, Jalai A, Amirsardari Z, Sahebjam M, et al. Three‐dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure. Echocardiography. 2024. doi:10.1111/echo.15822
BibTeX
@article{Narimani2024,
author = {Narimani, Sima and Ayati, Aryan and Tayebi, Amirhossein and Jalai, Arash and Amirsardari, Zahra and Sahebjam, Mohammad and Zoroufian, Arezou},
title = {Three‐dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.15822}
}
EUVIMED