An attention‐based deep learning method for right ventricular quantification using 2D echocardiography: Feasibility and accuracy
Echocardiography · 2024
DOI: 10.1111/echo.15719 ↗Kurz gefasst
Fachartikel in der Zeitschrift Echocardiography, 2024. Verfasst von Polydoros N Kampaktsis und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA. Hauptthemen laut MEDLINE: Deep Learning, Ventricular Dysfunction, Right. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Dr. Ted Goldstein.
Abstract (Originalsprache)
Aim
To test the feasibility and accuracy of a new attention‐based deep learning (DL) method for right ventricular (RV) quantification using 2D echocardiography (2DE) with cardiac magnetic resonance imaging (CMR) as reference. Methods and Results We retrospectively analyzed images from 50 adult patients (median age 51, interquartile range 32–62 42% women) who had undergone CMR within 1 month of 2DE. RV planimetry of the myocardial border was performed in end‐diastole (ED) and end‐systole (ES) for eight standardized 2DE RV views with calculation of areas. The DL model comprised a Feature Tokenizer module and a stack of Transformer layers. Age, gender and calculated areas were used as inputs, and the output was RV volume in ED/ES. The dataset was randomly split into training, validation and testing subsets (35, 5 and 10 patients respectively). Mean RVEDV, RVESV and RV ejection fraction (EF) were 163 ± 70 mL, 82 ± 42 mL and 51% ± 8% respectively without differences among the subsets. The proposed method achieved good prediction of RV volumes (R 2 = .953, absolute percentage error [APE] = 9.75% ± 6.23%) and RVEF (APE = 7.24% ± 4.55%). Per CMR, there was one patient with RV dilatation and three with RV dysfunction in the testing dataset. The DL model detected RV dilatation in 1/1 case and RV dysfunction in 4/3 cases.
Conclusions
An attention‐based DL method for 2DE RV quantification showed feasibility and promising accuracy. The method requires validation in larger cohorts with wider range of RV size and function. Further research will focus on the reduction of the number of required 2DE to make the method clinically applicable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA.
- School of Science and Technology, Nottingham Trent University, Nottingham, UK.
- Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA.
- Department of Radiology, Columbia University Irving Medical Center, New York, New York, USA.
- Department of Biostatistics, Columbia University Irving Medical Center, New York, New York, USA.
- AiDEAS, Tallinn, Estonia.
ORCID-Profile: Polydoros N Kampaktsis
Förderung
- Dr. Ted Goldstein
Zitieren
APA
Kampaktsis, P. N., Bohoran, T. A., Lebehn, M., McLaughlin, L., Leb, J., Liu, Z., Moustakidis, S., Siouras, A., Singh, A., Hahn, R. T., McCann, G. P., & Giannakidis, A. (2024). An attention‐based deep learning method for right ventricular quantification using 2D echocardiography: Feasibility and accuracy. Echocardiography. https://doi.org/10.1111/echo.15719
Vancouver
Kampaktsis PN, Bohoran TA, Lebehn M, McLaughlin L, Leb J, Liu Z, et al. An attention‐based deep learning method for right ventricular quantification using 2D echocardiography: Feasibility and accuracy. Echocardiography. 2024. doi:10.1111/echo.15719
BibTeX
@article{Kampaktsis2024,
author = {Kampaktsis, Polydoros N and Bohoran, Tuan A and Lebehn, Mark and McLaughlin, Laura and Leb, Jay and Liu, Zhonghua and Moustakidis, Serafeim and Siouras, Athanasios and Singh, Anvesha and Hahn, Rebecca T and McCann, Gerry P and Giannakidis, Archontis},
title = {An attention‐based deep learning method for right ventricular quantification using 2D echocardiography: Feasibility and accuracy},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.15719}
}
EUVIMED