EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems

Katrine Bovién Gørlitz iD, Sara Heebøll, Morten Fenger-Grøn, Sanne Fisker, Søren Gregersen, Christian Trolle, Klavs Würgler Hansen

Diabetes, Obesity and Metabolism · 05.11.2026

DOI: 10.1111/dom.71486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes, Obesity and Metabolism, online erschienen am 05.11.2026. Verfasst von Katrine Bovién Gørlitz und 6 weiteren Autor:innen. Beteiligte Einrichtung: Medical Diagnostic Center, University Clinic for Innovative Patient Pathways, Regional Hospital Central Jutland, Silkeborg/Viborg, Denmark. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The glucose management indicator (GMI) estimates HbA1c from continuous glucose monitoring (CGM)‐derived mean glucose. We assessed whether this relationship differs between contemporary CGM systems. Materials and Methods In this observational study, mean sensor glucose was derived from 2 months of CGM data preceding HbA1c measurement in adults with Type 1 diabetes using Dexcom (Dx) G6/G7 ( n = 252) or Medtronic Guardian 4/Simplera (GSi) ( n = 180). Device‐specific GMI equations were derived using linear regression of measured HbA1c on mean sensor glucose and compared with the original GMI equation. For direct comparison of the Dx and GSi GMI equations, these GMI equations were combined, with 95% confidence intervals calculated using the delta method.

Results

The Dx GMI equation yielded statistically significantly lower GMI values compared with the original GMI equation at mean sensor glucose levels < 13.7 mmol/L, with increasing differences at lower glucose levels. Conversely, at mean sensor glucose levels above 8.3 mmol/L, the GSi GMI equation yielded statistically significantly higher GMI values than the original GMI equation, with increasing differences at higher glucose levels. The Dx and GSi device‐specific GMI equations yielded statistically significantly different GMI values > 6.7 mmol/L, with increasing differences at higher glucose levels.

Conclusions

The relationship between mean sensor glucose and HbA1c differed between contemporary CGM systems. This finding suggests that device‐specific GMI equations may improve interpretation of glycaemic control in the absence of standardisation across contemporary CGM systems.

Schlagwörter

Stichwörter der Autor:innen

Type 1 diabetescontinuous glucose monitoring (CGM)database researchglycaemic control

Autor:innen und Institutionen

  • Medical Diagnostic Center, University Clinic for Innovative Patient Pathways, Regional Hospital Central Jutland, Silkeborg/Viborg, Denmark.
  • Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Medical Department, Gødstrup Regional Hospital, Gødstrup, Denmark.
  • Steno Diabetes Center Aarhus, Aarhus University Hospital, Aarhus, Denmark.

ORCID-Profile: Katrine Bovién Gørlitz

Zitieren

APA

Gørlitz, K. B., Heebøll, S., Fenger-Grøn, M., Fisker, S., Gregersen, S., Trolle, C., & Hansen, K. W. (2026). Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.71486

Vancouver

Gørlitz KB, Heebøll S, Fenger-Grøn M, Fisker S, Gregersen S, Trolle C, et al. Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems. Diabetes, Obesity and Metabolism. 2026. doi:10.1111/dom.71486

BibTeX
@article{Grlitz2026,
  author = {Gørlitz, Katrine Bovién and Heebøll, Sara and Fenger-Grøn, Morten and Fisker, Sanne and Gregersen, Søren and Trolle, Christian and Hansen, Klavs Würgler},
  title = {Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems},
  journal = {Diabetes, Obesity and Metabolism},
  year = {2026},
  doi = {10.1111/dom.71486}
}
Kostenlos starten →