A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis
Diabetes, Obesity and Metabolism · 2026
DOI: 10.1111/dom.70575 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Diabetes, Obesity and Metabolism, 2026. Verfasst von Rachael J L Tan und 11 weiteren Autor:innen. Beteiligte Einrichtung: Diabetes Research Department, Faculty of Life Sciences and Medicine, King's College London, London, UK. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Gastroparesis, Insulin Infusion Systems, Insulin. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Clinical Lectureship, NIHR Clinician Scientist Fellowship.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Aims
A retrospective observational cohort study evaluating real‐world outcomes in adults with type 1 diabetes and gastroparesis using automated hybrid closed loop insulin delivery systems (HCL). Materials and Methods All adults with type 1 diabetes and gastroparesis attending King's College Hospital diabetes service and using continuous glucose monitoring (CGM) from 5 October 2023 to 16 January 2025 were included. Glycaemic data (HbA 1c , CGM metrics), hypoglycaemia awareness (Gold score), diabetes distress (DDS2), and acute complications (DKA, severe hypoglycaemia) were collected from electronic health records and glucose platforms for 12 months pre‐ and post‐HCL initiation.
Results
From 1827 clinic attendees, 36 adults with gastroparesis were identified, with 17 initiating HCL. HCL and non‐HCL groups had comparable baseline characteristics and metrics (HCL: Mean(SD) HbA 1c 70(21)mmol/mol [8.6(1.9)%]; Time in range (TIR) 36.8 (21.9) % vs. non‐HCL: HbA 1c 71 (25) mmol/mol [8.6(2.3)%]; TIR 37.1(19.2)%, p = 0.73). Post‐HCL, HbA 1c median(IQR) fell to 57(52.5–65.0) mmol/mol [7.4(7.0–8.1)%] ( p < 0.001). TIR increased to 55.7(19.9)% ( p < 0.001), with a significant reduction in Time above range Level 2 (TAR2) [>13.9 mmol/L/>250 mg/dL](32.7% to 14.5%, p = 0.014). Gold score improved (2.5 to 1.5, p = 0.019), but DDS2 remained unchanged. No increase in DKA or severe hypoglycaemia occurred.
Conclusions
Within a specialist multidisciplinary team setting, HCL systems significantly reduce HbA 1c without increasing risk of severe hypoglycaemia or DKA in people with type 1 diabetes and gastroparesis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Diabetes Research Department, Faculty of Life Sciences and Medicine, King's College London, London, UK.
- Department of Diabetes, King's College Hospital NHS Foundation Trust, London, UK.
- Department of Gastroenterology King's College Hospital NHS Foundation Trust, London, UK.
ORCID-Profile: Rachael J L Tan, Marietta Stadler
Förderung
- NIHR Clinical Lectureship
- NIHR Clinician Scientist Fellowship
Zitieren
APA
Tan, R. J. L., Ahuja, A., Shrestha, A., Gallen, G., Stotesbury, B., Cheah, Y., Mustafa, O. G., Whyte, M. B., Croos, J., Shooshtarian, A., Hayee, B. H., & Stadler, M. (2026). A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.70575
Vancouver
Tan RJL, Ahuja A, Shrestha A, Gallen G, Stotesbury B, Cheah Y, et al. A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis. Diabetes, Obesity and Metabolism. 2026. doi:10.1111/dom.70575
BibTeX
@article{Tan2026,
author = {Tan, Rachael J L and Ahuja, Anusha and Shrestha, Aakanksha and Gallen, Geraldine and Stotesbury, Ben and Cheah, Yee and Mustafa, Omar G and Whyte, Martin B and Croos, Jonathan and Shooshtarian, Adam and Hayee, Bu' Hussain and Stadler, Marietta},
title = {A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis},
journal = {Diabetes, Obesity and Metabolism},
year = {2026},
doi = {10.1111/dom.70575}
}
EUVIMED