EUVIMEDEUVIMED entdecken
Qualitative StudieOpen Access · CC BY-NC-ND 4.0

Continuous glucose monitoring remote monitoring does not meet the needs of all adult users: A qualitative study of adults with type 1 diabetes who do not use remote monitoring

Anjana Rathan, Alisa Boucsein, Hamish Crocket, Benjamin J Wheeler

Diabetic Medicine · 2025

DOI: 10.1111/dme.70120 ↗

Kurz gefasst

Qualitative Studie in der Zeitschrift Diabetic Medicine, 2025. Verfasst von Anjana Rathan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatrics and Child Health, Dunedin School of Medicine, Otago Medical School, University of Otago, Dunedin, New Zealand. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Blood Glucose Self-Monitoring, Blood Glucose. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Division of Health Sciences, University of Otago.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Continuous glucose monitoring (CGM) is increasingly popular in the management of type 1 diabetes (T1D). These devices have a remote monitoring function that allows for a third‐party individual to monitor the user's glucose levels. While remote monitoring in CGM devices is widely used in T1D management, especially in paediatric populations, there are some individuals with T1D that do not utilise this function. This study aimed to explore the reasons behind some adults not using the remote following function on their real‐time CGM (rtCGM) devices.

Methods

Adults with T1D who had been using rtCGM without the remote monitoring function were invited to participate in a semi‐structured interview. Interviews explored the participants' experiences using CGM and their reasons on why remote monitoring was not for them. Interviews were analysed thematically.

Results

Interviews were conducted with fifteen people with T1D. Mean age was 27.3 years ± 9.34 SD. Thematic analysis identified three remote monitoring themes: (1) anxiety/concern regarding sharing data; (2) independence with diabetes management; and (3) desire for more customised sharing. There was a universal appeal of the efficacy, ease and practicality of glucose management with CGM devices among participants, particularly when compared to their past experiences with finger‐prick testing.

Conclusions

Remote monitoring can be a valuable complement to CGM, but it may not appeal to all individuals with T1D, particularly some adults. These findings offer insights for healthcare teams and provide feedback to help CGM manufacturers develop a more customised remote monitoring experience. Some users clearly wish to prioritise privacy and autonomy while still gaining a safety net in critical situations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 1Blood Glucose Self-MonitoringBlood GlucoseHumansAdultFemaleMaleQualitative ResearchYoung AdultMiddle AgedTelemedicineContinuous Glucose Monitoring

Stichwörter der Autor:innen

continuous blood glucose monitoringdiabetesqualitative methods

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Paediatrics and Child Health, Dunedin School of Medicine, Otago Medical School, University of Otago, Dunedin, New Zealand.
  • Division of Health, School of Health Equity and Innovation, University of Waikato, Hamilton, New Zealand.
  • Paediatric Endocrinology, Health New Zealand - Southern, Dunedin, New Zealand.

Förderung

  • Division of Health Sciences, University of Otago

Zitieren

APA

Rathan, A., Boucsein, A., Crocket, H., & Wheeler, B. J. (2025). Continuous glucose monitoring remote monitoring does not meet the needs of all adult users: A qualitative study of adults with type 1 diabetes who do not use remote monitoring. Diabetic Medicine. https://doi.org/10.1111/dme.70120

Vancouver

Rathan A, Boucsein A, Crocket H, Wheeler BJ. Continuous glucose monitoring remote monitoring does not meet the needs of all adult users: A qualitative study of adults with type 1 diabetes who do not use remote monitoring. Diabetic Medicine. 2025. doi:10.1111/dme.70120

BibTeX
@article{Rathan2025,
  author = {Rathan, Anjana and Boucsein, Alisa and Crocket, Hamish and Wheeler, Benjamin J},
  title = {Continuous glucose monitoring remote monitoring does not meet the needs of all adult users: A qualitative study of adults with type 1 diabetes who do not use remote monitoring},
  journal = {Diabetic Medicine},
  year = {2025},
  doi = {10.1111/dme.70120}
}
Kostenlos starten →