Multizentrische Studie in der Zeitschrift Digestive Endoscopy, online erschienen am 14.07.2026. Verfasst von Haruka Toyonaga und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Kansai Medical University Medical Center, Osaka, Japan. Hauptthemen laut MEDLINE: Cholangiopancreatography, Endoscopic Retrograde, Pancreatic Diseases, Natural Orifice Endoscopic Surgery, Biliary Tract Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peroral cholangiopancreatoscopy (POCPS) is established for diagnosis and treatment of pancreatobiliary diseases in patients with normal anatomy, but has been difficult to perform in patients with surgically altered anatomy (SAA) because conventional cholangioscope systems cannot pass through the working channel of balloon endoscopes. The novel 9Fr cholangioscope (eyeMAX 9Fr; Micro‐Tech) has a 3.2‐mm outer diameter, enabling passage through the 3.2‐mm working channel of short‐type balloon endoscopes and allowing through‐the‐channel POCPS during balloon endoscopy‐assisted ERCP (BE‐ERCP) without scope exchange. We retrospectively evaluated 38 consecutive BE‐POCPS procedures using the eyeMAX 9Fr in patients with SAA at two tertiary centers in Japan. Indications included biliary stone ( n = 31), pancreatobiliary stricture ( n = 4), pancreatic stone ( n = 1), cystic duct selection ( n = 1), and migrated stent retrieval ( n = 1). Technical success was achieved in all 38 cases (100%) across five reconstruction types using both single‐balloon and double‐balloon endoscopes. For lithotripsy ( n = 32), stone fragmentation was successful in all cases, with single‐session complete stone clearance in 53.1%. For stricture evaluation ( n = 4), visual assessment–final diagnosis concordance was 75.0% (3/4) and biopsy adequacy rate was 75% (3/4); biopsy–final diagnosis concordance was 100% among adequate specimens (3/3). Adverse events occurred in three cases (7.9%), including lithotripsy‐related bile duct mucosal injury/bleeding ( n = 2), and scope‐related small bowel perforation ( n = 1). BE‐POCPS using the eyeMAX 9Fr is a feasible and safe approach enabling direct visualization, targeted biopsy, and lithotripsy in SAA patients without scope exchange.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cholangiopancreatography, Endoscopic RetrogradePancreatic DiseasesNatural Orifice Endoscopic SurgeryBiliary Tract DiseasesHumansRetrospective StudiesFemaleMaleMiddle AgedAgedEquipment DesignTreatment OutcomeAged, 80 and overAdult

Stichwörter der Autor:innen

balloon endoscopycholangioscopyelectrohydraulic lithotripsypancreatoscopysurgically altered anatomy

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Kansai Medical University Medical Center, Osaka, Japan.
  • Department of Gastroenterology, Saitama Medical University International Medical Center, Hidaka, Japan.

ORCID-Profile: Haruka Toyonaga, Akashi Fujita

Zitieren

APA

Toyonaga, H., Tanisaka, Y., Masaki, M., Oka, A., Okita, A., Osaki, F., Matsuno, Y., Takayama, S., Nakata, H., Takayama, T., Nakagawa, T., Orino, M., Matsumoto, H., Hamamura, R., Watanabe, R., Ito, S., Fujita, A., Mizuide, M., Ryozawa, S., & Shimatani, M. (2026). Efficacy and Safety of Balloon Endoscopy‐Assisted Peroral Cholangiopancreatoscopy ( POCPS ) Using a Novel 9Fr Cholangioscope in Patients With Surgically Altered Anatomy: A Dual‐Center Retrospective Study (With Video). Digestive Endoscopy, 38(7). https://doi.org/10.1111/den.70237

Vancouver

Toyonaga H, Tanisaka Y, Masaki M, Oka A, Okita A, Osaki F, et al. Efficacy and Safety of Balloon Endoscopy‐Assisted Peroral Cholangiopancreatoscopy ( POCPS ) Using a Novel 9Fr Cholangioscope in Patients With Surgically Altered Anatomy: A Dual‐Center Retrospective Study (With Video). Digestive Endoscopy. 2026;38(7). doi:10.1111/den.70237

BibTeX
@article{Toyonaga2026,
  author = {Toyonaga, Haruka and Tanisaka, Yuki and Masaki, Makoto and Oka, Arata and Okita, Akihiro and Osaki, Fumiya and Matsuno, Yoshiki and Takayama, Shoji and Nakata, Hidetoshi and Takayama, Takuya and Nakagawa, Tatsuya and Orino, Masahiro and Matsumoto, Hironao and Hamamura, Ryosuke and Watanabe, Ryuichi and Ito, Suguru and Fujita, Akashi and Mizuide, Masafumi and Ryozawa, Shomei and Shimatani, Masaaki},
  title = {Efficacy and Safety of Balloon Endoscopy‐Assisted Peroral Cholangiopancreatoscopy ( POCPS ) Using a Novel 9Fr Cholangioscope in Patients With Surgically Altered Anatomy: A Dual‐Center Retrospective Study (With Video)},
  journal = {Digestive Endoscopy},
  year = {2026},
  volume = {38},
  number = {7},
  doi = {10.1111/den.70237}
}
Kostenlos starten →