EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieVergleichsstudieOpen Access · CC BY-NC 4.0

Effectiveness and Safety of Enteroscopy‐Assisted ERP ‐Guided Versus EUS ‐Guided Pancreatic Duct Drainage for Pancreaticojejunostomy Strictures: A Multicenter Observational Study

Shogo Ota iD, Hideyuki Shiomi iD, Yuki Fujii, Kazuyuki Matsumoto, Masataka Kano, Masaaki Shimatani iD, Naoki Fujita iD, Hideki Kamada, Saori Ueno, Takeshi Ogura iD, Mamoru Takenaka iD, Kae Nagao und 13 weitere

Digestive Endoscopy · 2026-03 · 38 (3)

DOI: 10.1111/den.70128 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Digestive Endoscopy, online erschienen am 27.02.2026. Verfasst von Shogo Ota und 24 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology, Hyogo Medical University, Nishinomiya, Japan. Hauptthemen laut MEDLINE: Pancreaticojejunostomy, Pancreatic Ducts, Drainage, Endosonography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Enteroscopy‐assisted endoscopic retrograde pancreatography‐guided pancreatic duct drainage (eERP‐PDD) and endoscopic ultrasound‐guided pancreatic duct drainage (EUS‐PDD) are minimally invasive alternatives to surgery for pancreaticojejunostomy stricture (PJS); however, comparative data remain limited. We compared the effectiveness and safety of these approaches and identified factors associated with technical failure.

Methods

This multicenter retrospective study included 88 patients (111 procedures) who underwent endoscopic intervention for PJS at 13 Japanese tertiary centers. We compared clinical outcomes between eERP‐PDD and EUS‐PDD. The primary outcome was technical success; secondary outcomes included clinical success, procedure time, and adverse events (AEs). Propensity‐score overlap weighting was used to adjust for baseline differences.

Results

As initial treatment, 77 patients underwent eERP‐PDD and 11 underwent EUS‐PDD. After adjustment, EUS‐PDD achieved higher technical success (eERP‐PDD, 28% vs. EUS‐PDD, 71%; p = 0.012) and clinical success (22% vs. 71%; p = 0.003), with shorter procedure time (76 min vs. 41 min; p = 0.001). AE incidence was higher with EUS‐PDD before adjustment (5% vs. 27%; p = 0.039) but comparable after adjustment (7% vs. 29%; p = 0.15); all AEs resolved with conservative management. Age < 75 years, male sex, and main pancreatic duct (MPD) diameter ≥ 5 mm were independently associated with eERP‐PDD failure.

Conclusions

EUS‐PDD demonstrated higher technical and clinical success than eERP‐PDD for PJS, with comparable safety after adjustment. An MPD diameter ≥ 5 mm was associated with eERP‐PDD failure. An MPD‐based algorithm is proposed: eERP‐PDD for MPD < 5 mm with EUS‐PDD as salvage, and EUS‐PDD for MPD ≥ 5 mm. This algorithm is hypothesis‐generating and requires prospective validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PancreaticojejunostomyPancreatic DuctsDrainageEndosonographyCholangiopancreatography, Endoscopic RetrogradeHumansMaleFemaleRetrospective StudiesTreatment OutcomeConstriction, PathologicAgedMiddle AgedJapanSurgery, Computer-Assisted

Stichwörter der Autor:innen

endoscopic ultrasound‐guided pancreatic duct drainageenteroscopy‐assisted endoscopic retrograde pancreatography‐guided pancreatic du…main pancreatic duct diameterpancreaticojejunostomy stricturepropensity score overlap weighting

Autor:innen und Institutionen

  • Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology, Hyogo Medical University, Nishinomiya, Japan.
  • Department of Gastroenterology and Hepatology, Okayama University Hospital, Okayama, Japan.
  • Division of Gastroenterology and Hepatology, Kansai Medical University Medical Center, Osaka, Japan.
  • Department of Gastroenterology and Neurology, Kagawa University, Miki-cho Kita-gun, Japan.
  • Second Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan.
  • Department of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka, Japan.

ORCID-Profile: Shogo Ota, Hideyuki Shiomi, Masaaki Shimatani, Naoki Fujita, Takeshi Ogura, Mamoru Takenaka, Arata Sakai, Osamu Inatomi, Koh Kitagawa, Ryota Nakano, Akihisa Ohno, Nao Fujimori, Masayuki Kitano

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Ota, S., Shiomi, H., Fujii, Y., Matsumoto, K., Kano, M., Shimatani, M., Fujita, N., Kamada, H., Ueno, S., Ogura, T., Takenaka, M., Nagao, K., Sakai, A., Shintani, S., Inatomi, O., Kitagawa, K., Nakano, R., Koizumi, M., Imamura, Y., …, & Kitano, M. (2026). Effectiveness and Safety of Enteroscopy‐Assisted ERP ‐Guided Versus EUS ‐Guided Pancreatic Duct Drainage for Pancreaticojejunostomy Strictures: A Multicenter Observational Study. Digestive Endoscopy, 38(3). https://doi.org/10.1111/den.70128

Vancouver

Ota S, Shiomi H, Fujii Y, Matsumoto K, Kano M, Shimatani M, et al. Effectiveness and Safety of Enteroscopy‐Assisted ERP ‐Guided Versus EUS ‐Guided Pancreatic Duct Drainage for Pancreaticojejunostomy Strictures: A Multicenter Observational Study. Digestive Endoscopy. 2026;38(3). doi:10.1111/den.70128

BibTeX
@article{Ota2026,
  author = {Ota, Shogo and Shiomi, Hideyuki and Fujii, Yuki and Matsumoto, Kazuyuki and Kano, Masataka and Shimatani, Masaaki and Fujita, Naoki and Kamada, Hideki and Ueno, Saori and Ogura, Takeshi and Takenaka, Mamoru and Nagao, Kae and Sakai, Arata and Shintani, Shuhei and Inatomi, Osamu and Kitagawa, Koh and Nakano, Ryota and Koizumi, Mitsuhito and Imamura, Yoshiki and Ohno, Akihisa and Fujimori, Nao and Tamura, Takaaki and Miyagahara, Tsukasa and Nakajima, Mikio and Kitano, Masayuki},
  title = {Effectiveness and Safety of Enteroscopy‐Assisted ERP ‐Guided Versus EUS ‐Guided Pancreatic Duct Drainage for Pancreaticojejunostomy Strictures: A Multicenter Observational Study},
  journal = {Digestive Endoscopy},
  year = {2026},
  volume = {38},
  number = {3},
  doi = {10.1111/den.70128}
}
Kostenlos starten →