EUVIMEDEUVIMED entdecken
Video/AudioOpen Access · CC BY 4.0

Verification in an animal study of the appropriate settings for a novel radiofrequency generator in radiofrequency ablation therapy for residual intraductal lesions after endoscopic papillectomy (with video)

Kenjiro Yamamoto, Takao Itoi iD, Atsushi Sofuni, Takayoshi Tsuchiya, Reina Tanaka, Ryosuke Tonozuka iD, Kazumasa Nagai, Yukitoshi Matsunami, Hiroyuki Kojima, Hirohito Minami, Noriyuki Hirakawa iD, Kyoko Asano iD und 1 weitere

Digestive Endoscopy · 2025

DOI: 10.1111/den.14986 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Digestive Endoscopy, 2025. Verfasst von Kenjiro Yamamoto und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan. Hauptthemen laut MEDLINE: Radiofrequency Ablation, Pancreatic Neoplasms, Carcinoma, Pancreatic Ductal, Catheter Ablation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoscopic intraductal radiofrequency ablation (ID‐RFA) can curatively treat residual intraductal lesions after endoscopic papillectomy. This study aimed to verify the tissue invasiveness of ID‐RFA using a novel RF generator and to explore its appropriate settings in an animal experiment, followed by a small clinical study. Pig liver specimens were ablated using a dedicated RF catheter and two RF generators to investigate structural differences between them and the ablation effects produced under various voltage and power settings. Appropriate settings for the novel generator were sought to provide an ablation effect equivalent to that with the recommended settings for a conventional generator. The ablation effect was also observed at various ablation times in vitro. Then we performed ID‐RFA in five patients. Each generator has a different structure, and no novel generator settings are identical to the recommended conventional generator settings. Obtaining adequate ablation requires both sufficient power and sufficient voltage. Based on the validation experiments, we concluded that the appropriate novel generator settings were 125 Vp and 30 W for 30 s. In the clinical study, good tumor ablation was obtained with no recurrence after a single ID‐RFA treatment, although the incidence of ductal stricture was relatively high. ID‐RFA for residual intraductal lesions may potentially be curative. However, excessive ablation should be avoided. To ensure safe and effective ID‐RFA, a thorough understanding of the RF generator specifications is required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiofrequency AblationPancreatic NeoplasmsCarcinoma, Pancreatic DuctalCatheter AblationSphincterotomy, EndoscopicAnimalsSwineHumansFemaleMaleAgedNeoplasm, ResidualMiddle AgedCholangiopancreatography, Endoscopic Retrograde

Stichwörter der Autor:innen

ampullary adenomaanimal experimentendoscopic papillectomyradiofrequency ablationresidual intraductal lesion

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan.

ORCID-Profile: Takao Itoi, Ryosuke Tonozuka, Noriyuki Hirakawa, Kyoko Asano, Shuntaro Mukai

Zitieren

APA

Yamamoto, K., Itoi, T., Sofuni, A., Tsuchiya, T., Tanaka, R., Tonozuka, R., Nagai, K., Matsunami, Y., Kojima, H., Minami, H., Hirakawa, N., Asano, K., & Mukai, S. (2025). Verification in an animal study of the appropriate settings for a novel radiofrequency generator in radiofrequency ablation therapy for residual intraductal lesions after endoscopic papillectomy (with video). Digestive Endoscopy. https://doi.org/10.1111/den.14986

Vancouver

Yamamoto K, Itoi T, Sofuni A, Tsuchiya T, Tanaka R, Tonozuka R, et al. Verification in an animal study of the appropriate settings for a novel radiofrequency generator in radiofrequency ablation therapy for residual intraductal lesions after endoscopic papillectomy (with video). Digestive Endoscopy. 2025. doi:10.1111/den.14986

BibTeX
@article{Yamamoto2025,
  author = {Yamamoto, Kenjiro and Itoi, Takao and Sofuni, Atsushi and Tsuchiya, Takayoshi and Tanaka, Reina and Tonozuka, Ryosuke and Nagai, Kazumasa and Matsunami, Yukitoshi and Kojima, Hiroyuki and Minami, Hirohito and Hirakawa, Noriyuki and Asano, Kyoko and Mukai, Shuntaro},
  title = {Verification in an animal study of the appropriate settings for a novel radiofrequency generator in radiofrequency ablation therapy for residual intraductal lesions after endoscopic papillectomy (with video)},
  journal = {Digestive Endoscopy},
  year = {2025},
  doi = {10.1111/den.14986}
}
Kostenlos starten →