Novel perfusion system using continuous liquid‐suction catheter attachment in colorectal endoscopic submucosal dissection with water pressure method (with video)

Teppei Masunaga iD, Yusaku Takatori, Motoki Sasaki, Moe Sato, Daisuke Minezaki, Kohei Morioka, Anna Tojo, Hinako Sakurai, Kentaro Iwata iD, Kurato Miyazaki, Yoko Kubosawa iD, Mari Mizutani und 9 weitere

Digestive Endoscopy · 2024-09 · 36 (9) · 1043-1050

DOI: 10.1111/den.14870 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Digestive Endoscopy, online erschienen am 08.07.2024. Verfasst von Teppei Masunaga und 20 weiteren Autor:innen. Beteiligte Einrichtung: Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan. Hauptthemen laut MEDLINE: Endoscopic Mucosal Resection, Colorectal Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Water pressure method (WPM) is useful for colorectal endoscopic submucosal dissection (ESD), characterized not only by underwater conditions but also by active water pressure via the waterjet function. However, the extension of the colorectum by injecting excess water and contaminating the operative field by stool and bleeding have been issues. This study aimed to evaluate the feasibility of a novel perfusion system using a continuous liquid‐suction catheter attachment (CLCA) in colorectal ESD with WPM. We retrospectively reviewed cases in which the perfusion system was used in colorectal ESD with WPM between August 2022 and September 2023. We evaluated clinical characteristics, treatment outcomes, volume of injection by the waterjet function, volume of suction by the endoscope and CLCA, and concentration of floating matter in the operative field over time. Thirty‐one cases were enrolled. The median lesion size was 30 (range, 15–100) mm. In all cases, en bloc resection was achieved without perforation. The median injection volume was 2312 (range, 1234–13,866) g. The median suction volumes by the endoscope and CLCA were 918 (range, 141–3162) and 1147 (range, 254–11,222) g, respectively. The median concentration of floating matter in the operative field (measured in 15 cases) was 15.3 (range, 7.3–112) mg/mL when the endoscope arrived at the lesion and 8.0 (range, 3.2–16) mg/mL after endoscopically washing at the beginning of the ESD. It ranged from 7.6 to 13.4 mg/dL every 20 min during ESD. This perfusion system could prevent the extension of the lumen and maintain a good field of view in colorectal ESD with WPM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endoscopic Mucosal ResectionColorectal NeoplasmsHumansMaleFemaleAgedRetrospective StudiesMiddle AgedSuctionAged, 80 and overFeasibility StudiesCathetersWaterPerfusionPressure

Stichwörter der Autor:innen

colorectal endoscopic submucosal dissectioncontinuous liquid‐suction catheter attachmentendoscopic submucosal dissectionunderwater endoscopic submucosal dissectionwater pressure method

Substanzen

Water

Autor:innen und Institutionen

  • Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan.
  • Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Tokyo, Japan.
  • Center for Diagnostic and Therapeutic Endoscopy, Keio University School of Medicine, Tokyo, Japan.
  • Department of Next Generation Endoscopic Intervention (Project ENGINE), Osaka University Graduate School of Medicine, Osaka, Japan.

ORCID-Profile: Teppei Masunaga, Kentaro Iwata, Yoko Kubosawa, Teppei Akimoto, Noriko Matsuura, Atsushi Nakayama, Kaoru Takabayashi, Kiyokazu Nakajima, Motohiko Kato

Zitieren

APA

Masunaga, T., Takatori, Y., Sasaki, M., Sato, M., Minezaki, D., Morioka, K., Tojo, A., Sakurai, H., Iwata, K., Miyazaki, K., Kubosawa, Y., Mizutani, M., Akimoto, T., Kawasaki, S., Matsuura, N., Nakayama, A., Sujino, T., Takabayashi, K., Nakajima, K., …, & Kato, M. (2024). Novel perfusion system using continuous liquid‐suction catheter attachment in colorectal endoscopic submucosal dissection with water pressure method (with video). Digestive Endoscopy, 36(9), 1043-1050. https://doi.org/10.1111/den.14870

Vancouver

Masunaga T, Takatori Y, Sasaki M, Sato M, Minezaki D, Morioka K, et al. Novel perfusion system using continuous liquid‐suction catheter attachment in colorectal endoscopic submucosal dissection with water pressure method (with video). Digestive Endoscopy. 2024;36(9):1043-1050. doi:10.1111/den.14870

BibTeX
@article{Masunaga2024,
  author = {Masunaga, Teppei and Takatori, Yusaku and Sasaki, Motoki and Sato, Moe and Minezaki, Daisuke and Morioka, Kohei and Tojo, Anna and Sakurai, Hinako and Iwata, Kentaro and Miyazaki, Kurato and Kubosawa, Yoko and Mizutani, Mari and Akimoto, Teppei and Kawasaki, Shintaro and Matsuura, Noriko and Nakayama, Atsushi and Sujino, Tomohisa and Takabayashi, Kaoru and Nakajima, Kiyokazu and Yahagi, Naohisa and Kato, Motohiko},
  title = {Novel perfusion system using continuous liquid‐suction catheter attachment in colorectal endoscopic submucosal dissection with water pressure method (with video)},
  journal = {Digestive Endoscopy},
  year = {2024},
  volume = {36},
  number = {9},
  pages = {1043--1050},
  doi = {10.1111/den.14870}
}