Endoscopic pressure study integrated system for the diagnosis of achalasia
Digestive Endoscopy · 2024
DOI: 10.1111/den.14695 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digestive Endoscopy, 2024. Verfasst von Yohei Nishikawa und 14 weiteren Autor:innen. Beteiligte Einrichtung: Digestive Diseases Center, Showa University Koto Toyosu Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Esophageal Achalasia, Manometry, Pressure. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Objectives
The endoscopic pressure study integrated system (EPSIS) is a novel diagnostic tool used to evaluate lower esophageal sphincter (LES) function. EPSIS allows the measurement of intragastric pressure (IGP) during gastric insufflation through esophagogastroduodenoscopy (EGD) and records its pressure waveform. This study aimed to assess the usefulness and applicability of EPSIS as an adjunct diagnostic modality for achalasia.
Methods
This case–control study was conducted using a database of patients who underwent EGD, barium swallow (BS), high‐resolution manometry (HRM), and EPSIS between January 2022 and December 2022. The achalasia (experimental) group ( n = 35) consisted of patients with a definitive diagnosis of achalasia. The control group ( n = 34) consisted of patients with no abnormalities in EGD, BS, or HRM and no abnormal acid reflux confirmed with 24‐h pH‐impedance monitoring. EPSIS findings were compared between the two groups and characterized by the waveform pattern (uphill or flat), maximum IGP (IGP‐Max), pressure difference, and the gradient of the waveform.
Results
All patients in the achalasia group showed an uphill pattern, in contrast to 21 patients (61.8%) in the control group. IGP‐Max demonstrated the best diagnostic accuracy for achalasia, with a cut‐off value of 15.8 mmHg (100% sensitivity, 58.8% specificity, and area under the curve [AUC] 0.78). The pressure gradient also demonstrated good diagnostic accuracy, with a cut‐off value of 0.40 mmHg/s (80% sensitivity, 61.8% specificity, and AUC 0.76).
Conclusion
This study demonstrated that EPSIS can be applied as a diagnostic modality in patients with achalasia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Digestive Diseases Center, Showa University Koto Toyosu Hospital, Tokyo, Japan.
- Institute of Digestive and Liver Diseases, St. Luke's Medical Center, Quezon City, Philippines.
ORCID-Profile: Yuto Shimamura, Yoshiaki Kimoto, Kazuki Yamamoto, Yusuke Fujiyoshi, Ippei Tanaka, Akiko Toshimori, Mayo Tanabe
Zitieren
APA
Nishikawa, Y., Inoue, H., Shimamura, Y., Navarro, M. J., Kawamata, N., Azuma, D., Ushikubo, K., Kimoto, Y., Yamamoto, K., Fujiyoshi, Y., Okada, H., Tanaka, I., Toshimori, A., Tanabe, M., & Onimaru, M. (2024). Endoscopic pressure study integrated system for the diagnosis of achalasia. Digestive Endoscopy. https://doi.org/10.1111/den.14695
Vancouver
Nishikawa Y, Inoue H, Shimamura Y, Navarro MJ, Kawamata N, Azuma D, et al. Endoscopic pressure study integrated system for the diagnosis of achalasia. Digestive Endoscopy. 2024. doi:10.1111/den.14695
BibTeX
@article{Nishikawa2024,
author = {Nishikawa, Yohei and Inoue, Haruhiro and Shimamura, Yuto and Navarro, Marc Julius and Kawamata, Natsuki and Azuma, Daisuke and Ushikubo, Kei and Kimoto, Yoshiaki and Yamamoto, Kazuki and Fujiyoshi, Yusuke and Okada, Hiroki and Tanaka, Ippei and Toshimori, Akiko and Tanabe, Mayo and Onimaru, Manabu},
title = {Endoscopic pressure study integrated system for the diagnosis of achalasia},
journal = {Digestive Endoscopy},
year = {2024},
doi = {10.1111/den.14695}
}
EUVIMED