EUVIMEDEUVIMED entdecken
Crossref

Cost‐effectiveness analysis of computer‐aided detection systems for colonoscopy in Japan

Masau Sekiguchi iD, Ataru Igarashi, Naoya Toyoshima, Hiroyuki Takamaru iD, Masayoshi Yamada iD, Minoru Esaki, Nozomu Kobayashi, Yutaka Saito iD

Digestive Endoscopy · 2023

DOI: 10.1111/den.14532 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digestive Endoscopy, 2023. Verfasst von Masau Sekiguchi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cancer Screening Center, National Cancer Center Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Cost-Effectiveness Analysis, Colorectal Neoplasms. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Cancer Center Research and Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The usefulness of computer‐aided detection systems (CADe) for colonoscopy has been increasingly reported. In many countries, however, data on the cost‐effectiveness of their use are lacking; consequently, CADe for colonoscopy has not been covered by health insurance. We aimed to evaluate the cost‐effectiveness of colonoscopy using CADe in Japan.

Methods

We conducted a simulation model analysis using Japanese data to examine the cost‐effectiveness of colonoscopy with and without CADe for a population aged 40–74 years who received colorectal cancer (CRC) screening with a fecal immunochemical test (FIT). The rates of receiving FIT screening and colonoscopy following a positive FIT were set as 40% and 70%, respectively. The sensitivities of FIT for advanced adenomas and CRC Dukes' A–D were 26.5% and 52.8–78.3%, respectively. CADe colonoscopy was judged to be cost‐effective when its incremental cost‐effectiveness ratio (ICER) was below JPY 5,000,000 per quality‐adjusted life‐years (QALYs) gained.

Results

Compared to conventional colonoscopy, CADe colonoscopy showed a higher QALY (20.4098 vs. 20.4088) and lower CRC incidence (2373 vs. 2415 per 100,000) and mortality (561 vs. 569 per 100,000). When the CADe cost was set at JPY 1000–6000, the ICER per QALY gained for CADe colonoscopy was lower than JPY 5,000,000 (JPY 796,328–4,971,274). The CADe cost threshold at which the ICER for CADe colonoscopy exceeded JPY 5,000,000 was JPY 6040.

Conclusions

Computer‐aided detection systems for colonoscopy has the potential to be cost‐effective when the CADe cost is up to JPY 6000. These results suggest that the insurance reimbursement of CADe for colonoscopy is reasonable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cost-Effectiveness AnalysisColorectal NeoplasmsHumansJapanCost-Benefit AnalysisColonoscopyEarly Detection of CancerComputers

Stichwörter der Autor:innen

colonoscopycolorectal cancer screeningcomputer-aided detectioncost-effectivenessfecal immunochemical test

Autor:innen und Institutionen

  • Cancer Screening Center, National Cancer Center Hospital, Tokyo, Japan.
  • Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan.
  • Division of Screening Technology, National Cancer Center Institute for Cancer Control, Tokyo, Japan.
  • Department of Health Economics and Outcomes Research, Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo, Japan.
  • Department of Public Health, Yokohama City University School of Medicine, Kanagawa, Japan.
  • Hepatobiliary and Pancreatic Surgery Division, National Cancer Center Hospital, Tokyo, Japan.

ORCID-Profile: Masau Sekiguchi, Hiroyuki Takamaru, Masayoshi Yamada, Yutaka Saito

Förderung

  • National Cancer Center Research and Development Fund

Zitieren

APA

Sekiguchi, M., Igarashi, A., Toyoshima, N., Takamaru, H., Yamada, M., Esaki, M., Kobayashi, N., & Saito, Y. (2023). Cost‐effectiveness analysis of computer‐aided detection systems for colonoscopy in Japan. Digestive Endoscopy. https://doi.org/10.1111/den.14532

Vancouver

Sekiguchi M, Igarashi A, Toyoshima N, Takamaru H, Yamada M, Esaki M, et al. Cost‐effectiveness analysis of computer‐aided detection systems for colonoscopy in Japan. Digestive Endoscopy. 2023. doi:10.1111/den.14532

BibTeX
@article{Sekiguchi2023,
  author = {Sekiguchi, Masau and Igarashi, Ataru and Toyoshima, Naoya and Takamaru, Hiroyuki and Yamada, Masayoshi and Esaki, Minoru and Kobayashi, Nozomu and Saito, Yutaka},
  title = {Cost‐effectiveness analysis of computer‐aided detection systems for colonoscopy in Japan},
  journal = {Digestive Endoscopy},
  year = {2023},
  doi = {10.1111/den.14532}
}
Kostenlos starten →