Reopenable clip‐over‐the‐line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility study
Digestive Endoscopy · 2023-05 · 35 (4) · 505-511
DOI: 10.1111/den.14466 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digestive Endoscopy, online erschienen am 02.12.2022. Verfasst von Tatsuma Nomura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Ise Red Cross Hospital, Mie, Japan. Hauptthemen laut MEDLINE: Endoscopic Mucosal Resection. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Objectives
Large mucosal defects following gastric endoscopic submucosal dissection (ESD) cause postoperative bleeding. To address this limitation and ensure closure of large mucosal defects, we developed the reopenable clip‐over‐the‐line method (ROLM) using a reopenable clip and nylon line. The purpose of this study was to evaluate the feasibility of the ROLM for closure of large mucosal defects following gastric ESD in a prospective, consecutive series of cases.
Methods
We performed the ROLM on 50 consecutive patients with gastric mucosal defects at the Ise Red Cross Hospital and Mie Prefectural Shima Hospital. The time to complete the ROLM, numbers of clips and lines required, size of defect, and closure success rate were measured, and postoperative adverse events were recorded.
Results
In all, 50 lesions were included in this study period between July 2021 and March 2022. The success rates of defect closure and defect closure without submucosal dead space of the ROLM were both 100% (50/50), with a median ROLM time of 30 (range, 14–35) min and a median resected specimen major axis of 45 (range, 31–73) mm. The median number of reopenable clips used was 31 (range, 10–93). Following gastric ESD, two cases of post‐ESD bleeding were observed during the follow‐up periods.
Conclusion
Our results suggest that ROLM is a feasible strategy for complete closure of mucosal defects post‐ESD without submucosal dead space. Future comparative studies with post‐ESD bleeding rate as the main outcome are desirable to evaluate the efficacy of ROLM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Ise Red Cross Hospital, Mie, Japan.
- Department of Gastroenterology, Mie Prefectural Shima Hospital, Mie, Japan.
ORCID-Profile: Tatsuma Nomura, Shinya Sugimoto
Zitieren
APA
Nomura, T., Sugimoto, S., Temma, T., Oyamada, J., Ito, K., & Kamei, A. (2023). Reopenable clip‐over‐the‐line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility study. Digestive Endoscopy, 35(4), 505-511. https://doi.org/10.1111/den.14466
Vancouver
Nomura T, Sugimoto S, Temma T, Oyamada J, Ito K, Kamei A. Reopenable clip‐over‐the‐line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility study. Digestive Endoscopy. 2023;35(4):505-511. doi:10.1111/den.14466
BibTeX
@article{Nomura2023,
author = {Nomura, Tatsuma and Sugimoto, Shinya and Temma, Taishi and Oyamada, Jun and Ito, Keiichi and Kamei, Akira},
title = {Reopenable clip‐over‐the‐line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility study},
journal = {Digestive Endoscopy},
year = {2023},
volume = {35},
number = {4},
pages = {505--511},
doi = {10.1111/den.14466}
}
EUVIMED